Dis 8, Handheld controller – Mallory Ignition ACCEL DIS 8 75610 User Manual

Page 17

Advertising
background image

DIS 8

17

Handheld Controller

The controller has a 9-pin DSUB socket which plugs into the on the end panel. The
controller does not need to be plugged in for the ignition to run, only to change the
settings. The control “modes’ are as listed below.

Setting

Range / Resolution

Action

Main RPML

1000-12800/100 RPM

Set maximum RPM limit

Auxiliary RPML

1000-12800/100 RPM

12 volts to White wire Pin
“F” on the Accessories
connector activates the
AUX RPML

High Speed Retard #1

.1-15 Degrees/.1 degrees

12 volts to Yellow wire Pin
“D” on the Accessories
connector activates the
High Speed Retard #1

Auxiliary RPML 2

1000-12800/100 RPM

12 volts to Purple wire Pin
“E” on the Accessories
connector activates the
RPM Limit #2

Start Retard

0-10 Degrees/.1 Degrees

Active only below 500 RPM

Window RPM Switch LO

Activation RPM

1000-12800/100 RPM

Supplies ground to the Red
wire Pin “A” on the
Accessories connector.
Activation RPM (low end of
RPM window)

Window RPM switch HI

De-activation RPM

1100-12800/100 RPM

Disables ground on the Red
wire Pin “A” on the
accessories connector. De-
activation RPM (upper end
of RPM window)

RPM Switch 2

1000-12800/100 RPM

Supplies ground to the
Black wire Pin “B” on the
Accessories connector at
set RPM.

RPM Switch 3

1000-12800/100 RPM

Supplies ground to the
Orange wire Pin “C” on the
Accessories connector at
set RPM.

Boost Retard

.1-4 Deg/PSI of boost/.1

Degrees

Retards Timing by number
of degrees per pound of
boost. A 2 or 3 bar MAP
sensor is required.

Number of Cylinders

4,5,6,8,10,12

Set number of Cylinders

MAP Sensor

2 is 2-bar sensor, 3 is 3-

bar sensor

A MAP sensor that has a
.2-4.8 volt output for the
full range can be used.

Advertising