Troubleshooting

Circuit breaker in handle tripped.

Reset breaker.

Belt is damaged

Replace belt

Debris is lodged in the brush housing

Remove debris

Switch is in OFF (O) position

Flip switch to ON (I) position.

Dome lid filter or vac float shut off may be
clogged

Rinse out items

Recovery dome lid is not seated properly. Reposition dome lid

Recovery tank is not seated properly over
intake tube.

Reposition recovery tank so the intake
tube is inserted into the inlet.

Recovery tank dump hose may not be
closed properly.

Disconnect cap from drain hose then
reconnect, to ensure the cap and hose
snap together.

Bad seals on recovery dome lid.

Check the gasket on the lid for damage.
Replace if needed.

Vac shoe may be clogged.

Check vac shoe for debris and remove if
necessary.

Vac shoe may be worn.

Replace vac shoe.

Circuit breaker in handle may have
tripped.

Reset breaker.

Motor carbon brush may be worn.

Contact a qualified service technician.

Switch is in the OFF (O) Position

Flip the switch to the ON (I) Position

Brush does not turn ON

Vacuum motor does not start.

Solution recovery is reduced

Advertising