INSPECTION

Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly inspected before shipment, and any
damage is the responsibility of the delivery carrier who should be notified immediately.

ELECTRICAL

Model Numbers X17115 / X17115HP are designed to operate on a standard 15 amp. 115 volt, 60 hz, AC circuit. Voltages below 105 volts
AC or above 125 volts AC could cause serious damage to the motor.
Model Numbers X17230 / X17230HP are designed to operate on a standard 10 amp. 230 volt, 50 hz, AC circuit. Voltages below 210 volts
AC or above 250 volts AC could cause serious damage to the motor.

WARNING

Electric motors can cause explosions when operated near explosive materials or vapors. Do not operate this machine near flammable
materials such as solvents, thinners, fuels, grain dust, etc.

GROUNDING INSTRUCTIONS

This floor-finishing machine shall be grounded while in use to protect the operator from electric shock. The machine is provided with a
three-conductor cord and a three-contact grounding type attachment plug to fit the proper grounding type receptacle. The green (or green
and yellow) conductor in the cord is the grounding wire. Never connect this wire to other than the grounding pin of the attachment plug.