4 setting the battery type, Maintenance and service – Minuteman Kleen Sweep KS 32 R (6400.40) User Manual

Page 50

Advertising
background image

50

Maintenance and Service

5.4.4

Setting the battery type

Adjustments to the total dis-
charge signal transducer may
only be completed at an autho-
rized Minuteman service cen-
ter.

The total discharge signal transducer
(Fig. 18/1) is located under the operat-
ing panel (Fig. 18/3). The various bat-
tery types can be setup using the
fourfold DIP Switch (Fig. 18/2).

* X1-6...X1-7 - open
** X1-6...X1-7 - jumper

Fig. 18
The two settings for GiV are equivalent.
The DIP setting OFF-ON-ON-OFF is
the preferred setting.

When battery sizes other than 100 Ah
to 117 Ah, the on-board charger must
be adjusted by Minuteman service tech-
nicians.

DIP1 DIP2 DIP3 DIP4 TYP

ON

OFF

OFF

OFF

Crown

ON

ON

OFF

ON

GiS

ON

OFF

ON

OFF

PzS

OFF

ON

ON

OFF

GiV

ON

ON

ON

OFF

PzV

OFF

OFF

OFF

ON

AGM

ON

ON

ON

ON

GiV*

ON

ON

ON

ON

PzS**