5.4.4
Setting the battery type
Adjustments to the total dis-
charge signal transducer may
only be completed at an autho-
rized Minuteman service cen-
ter.
The total discharge signal transducer
(Fig. 18/1) is located under the operat-
ing panel (Fig. 18/3). The various bat-
tery types can be setup using the
fourfold DIP Switch (Fig. 18/2).
* X1-6...X1-7 - open
** X1-6...X1-7 - jumper
Fig. 18
The two settings for GiV are equivalent.
The DIP setting OFF-ON-ON-OFF is
the preferred setting.
When battery sizes other than 100 Ah
to 117 Ah, the on-board charger must
be adjusted by Minuteman service tech-
nicians.
DIP1 DIP2 DIP3 DIP4 TYP
ON
OFF
OFF
OFF
Crown
ON
ON
OFF
ON
GiS
ON
OFF
ON
OFF
PzS
OFF
ON
ON
OFF
GiV
ON
ON
ON
OFF
PzV
OFF
OFF
OFF
ON
AGM
ON
ON
ON
ON
GiV*
ON
ON
ON
ON
PzS**
3
2
1