Before You Begin

First Time Operation

NOTE

The following is used to PRIME your new
MOTORVAC OILCLEAN-1000 SYSTEM, and is only
necessary the first time you use the unit.

NOTE

Do Not Operate Machine Below 50° Fahrenheit (10° Celsuis).

Detergent should be used / stored above 50°(10° Celsius).

1.

Remove OILCLEAN-1000 from box.

2.

Install new filter in unit’s filter bowl. (See page 4-4) Verify that the O’Ring is securely in place in the
plastic filter bowl

.

NOTE: Hand tighten filter only. Do not over tighten.

Check the output/return hoses, battery connections, and all external components for damage

.

3.

Open the one-gallon container of OILCLEAN-1000 cleaner detergent included with the starter kit
(This Starter Kit supplied in USA & Canada only). Shake container, place a funnel into unit’s fill
neck and carefully pour the contents into the unit’s tank. Note: The maximum capacity of the
unit’s reservoir is 72 OUNCES.

4.

Attach the unit to the vehicle's battery by connecting the red battery clip to the positive (+) battery
terminal and the black battery clip to a solid ground point as far from the battery as possible. Press
the MAIN POWER switch to on.

5.

Attach the adaptor #065-1033 to red OILCLEAN-1000 hose and insert into units tank fill neck.

6.

Press and hold the FILL switch until a solid stream of fluid is flowing out the RED hose adapter.

7. The

MOTORVAC OILCLEAN-1000 System is now ready for service. Press unit’s MAIN POWER

switch off.

8.

Proceed to Oil System Cleaning Procedures, page 4-1.