Troubleshooting and Additional Help


Refer to the list below in the unlikely event that you have problems with your

OilClean 1000.


Problem:

Solution:


1. The OilClean is not operational or

trips breaker immediately.

Polarity is reversed on vehicle battery connection.
Check connections for correct polarity. Check
circuit breaker on front of the cabinet.

2. Units Vehicle Oil Pressure Light stays

on when Engine is started.

Output and Return hoses may be reversed. Check
hoses for correct connection.

3. Fluid does not flow from tank to

vehicle when detergent fill switch is
held on.

Engine must be OFF. (Not running).
Engine oil may be cold. (Warm up engine & cycle
warm oil thru units’ hoses & filter).
Internal screen filter may be plugged up.
Pump may need to be ‘primed’.

4. The OilClean performs poorly.

Check all hoses and wires for cuts or frays.
Check cabinet for dents or impact markings.
Verify that the oil filter was replaced.

5. Sudden pressure drop on Vehicle
Pressure Gauge.

Blockage or restriction in black hose.