1812-065-U-12-13

23

2.3.2 System Set-up Code

Factory setting is 1 7 3 1.

These steps will program the system’s “Basic” set-up. The system set-up code is a four-digit number that will program the
1812 for:
1st digit: Single or multiple systems on the phone line. (Factory setting is “1” Single System)
2nd digit:
The systems attention number. The “attention number” is the number that the 1812 responds to when called
from the residence. If more than one 1812 is sharing the phone line, be sure the attention number to each system is
programmed with a unique attention number. (Factory setting is “7”)
3rd digit:
The number of rings to the house allowed before the system hangs up. (Factory setting is “3” Rings)
4th digit:
Single or double ring to the house. (Factory setting is “1” Double Ring)

You will need to enter a four-digit number in step 2 (see chart below) to program the system set-up code.

1. Press

*

0 4 and enter the MASTER CODE. [

*

0 4 _ _ _ _ (beep)]

2. Choose and enter a four-digit system set-up code (see chart below), then press

*

.

[ _ _ _ _

*

(beep)].

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

1st Digit (Step 2)

2nd Digit (Step 2)

3rd Digit (Step 2)

4th Digit (Step 2)

1 or 0

0 - 9

2 - 9

1 or 0

Enter “1” for a single system or “0” when multiple systems are sharing the same phone line.

System attention number. MUST be unique when using multiple systems on same phone line.

Number of home phone rings before the 1812 hangs up.

Enter “1” for the double ring or enter “0” for the standard long ring.

4 Digit System Set-up Code

Function

Valid #

2.3.1 Phone Mode or Intercom Mode

Factory setting is 1 (Phone Mode).

The 1812 is normally connected in series with a homeowner's incoming phone line, which supplies a constant source of
DC voltage. When the 1812 is connected in this manner, program the unit for PHONE mode.
If the 1812 is to be connected to an open C.O. (Central Office) port or through the internet on a key type telephone system.
If the 1812 is connected directly to a telephone without a C.O. or internet line, program the unit for INTERCOM mode. When
programmed in intercom mode, the 1812 will supply the constant DC voltage necessary for operation and will disconnect
the PHONE IN terminals 1 and 2 from the circuit board since these are not used in intercom mode.
If the 1812 is programmed for the intercom mode, the call forward and preprogrammed phone numbers “Dial a phone
number” features will not work.

1. Press

*

0 6 and enter the MASTER CODE. [

*

0 6 _ _ _ _ (beep)]

2. Press 1

*

for phone mode OR press 0

*

for intercom mode. [ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.3 Talk Time

Factory setting is 060 (60 Seconds).

This programming sequence sets the maximum time allowed for conversation when the 1812 places a call to the
homeowner's house, or if call forwarding is active, or if any of the dial out numbers are used. Talk time can be set from
1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk time
of 30 seconds, enter 030 in step 2.

1. Press

*

0 8 and enter the MASTER CODE. [

*

0 8 _ _ _ _ (beep)]

2. Enter the talk time code (001-255), then press

*

. [ _ _

*

(beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]