5 call forward time zone programming – DoorKing 1812 Classic User Manual

Page 30

Advertising
background image

1812-065-U-12-13

28

2.4.5 Call Forward Time Zone Programming

This programming sequence sets up a time zone for the call-forward feature. The 1812 must also have a call forward phone
number programmed into the 1812 memory (2.5.1). The call forward feature must be disabled (2.5.2) and the call forward
time zone feature must be enabled (4.6). It will automatically send calls to the forwarding phone number if the time and
day are within the time zone boundary that is programmed in this sequence. This feature is also dependent on the time and
day being outside the Do Not Disturb time zone boundary (2.4.2), if that has been programmed and enabled (4.7).

1. Press

*

3 7 and enter the MASTER CODE. [

*

3 7 _ _ _ _ (beep)]

2. Press 0

*

to turn time zone OFF, OR press 1

*

to turn time zone ON. [ _

*

(beep)]

3. Enter the beginning hour (01 to 12) and minutes (01 to 59), then press 0

*

for AM OR

press

1

*

for PM. [ _ _ _ _ then _

*

(beep)]

4. Enter the ending hour (01 to 12) and minutes (01 to 59), then press 0

*

for AM OR

press

1

*

for PM. [ _ _ _ _ then _

*

(beep)]

5. Enter the days of the week that the call forward time zone is to be active, then press

*

.

[ _ _ _ _ _ _ _

*

(beep)]

Sun =1, Mon = 2, Tue = 3, Wed = 4, Thu = 5, Fri = 6, Sat = 7.
Note: All 7 programming spaces must be populated. After all the desired day numbers have been
entered, enter # in all the existing unused spaces.
For example, for the call forward to be active monday through friday only, enter 2 3 4 5 6 # #

*

.

6. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.6 “Flash” Access Code Time Zone Programming (One Day Only)

“Flash” codes are access codes that are valid for a single day ONLY. Programming “flash” codes is a two-step process.
This programming sequence only schedules the day of the month that the “flash” access codes will be valid. Section 2.6.1
must still be programmed to enter the four-digit “flash” access codes. There is one “flash” access code per relay (2 total).

Note: The “flash” code will be valid for a single day only. For example, if you program a “flash” code on July 1st to be
valid on July 10th, the code will become valid on midnight July 10th, and expire on midnight July 11th. The “flash”
code will NOT become valid again on August 10th of the following month. For the existing “flash” code to function
again, it MUST be reprogrammed using the 5 steps above for a new valid day.

1. Press

*

4 5 and enter the MASTER CODE. [

*

4 5 _ _ _ _ (beep)]

2. Press 1 for relay 1 OR press 2 for relay 2, then press

*

. [ _

*

(beep)]

3. Enter the two-digit day of the month that the “flash” code is to be valid, then press

*

. [ _ _

*

(beep)]

4. Repeat steps 2 and 3 to set the other relay “flash” code if necessary.

5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]