2 wiring detail – large main cabinet, Page 21 – DoorKing 1816 Intercom System-Multi User Manual

Page 21

Advertising
background image

2.2 Wiring Detail – Large Main Cabinet

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

1816 Telephone Intercom System
Wiring Detail

Rev.

Title:

4/05

B

M1816-065-5

1 2 3 4

6

5

7 8 9 10

17

21

15

14

13

20

19

18

11 12

16

23 24

22

1 2 3 4

6

5

7 8 9 10

1816 Telephone Intercom System
Wiring Detail - Large Control Cabinet

C.O.
PHN

16 VAC

PWR

INPUT

INCOMING

C.O. PHN

LINES

7

8

3

Resident
Telephone

1

2

5

Lobby Panel

9

10

11

16 Volt, 40 VA UL Listed Transformer.

1

2

Earth Ground.

3

Optional Central Office phone line - touch tone, loop start.

4

Doorman Telephone (Optional).

5

Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for
additional wiring requirements.

6

Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.

7

Decoder board wiring, 18 AWG. Wire necessary decoder boards
corresponding terminals to corresponding terminals.

8

RJ71C phone block. See drawing M1816-065-6 for detail.

9

Incoming phone lines from Central Office.

10

Outgoing phone lines to individual apartments.

11

DoorKing connecting cable.

4

3

1 2

Doorman Telephone

4

6

6

1816-065-K-12-11

Page

21