2 board set-up, 1 elevator shaft identification, 2 floor identification – DoorKing 2348 Elevator Control User Manual

Page 16

Advertising
background image

3.2 Board

Set-up

The 2348-010 elevator boards must be set to identify to the access control system which elevator
shaft that it is in, and which floors in the elevator shaft that it is controlling. This programming function
is accomplished by the two DIP switches on the elevator control board, with each DIP switch having
eight (8) switches in them. The top switch is designated as SW-1 and the bottom switch is
designated as SW-2. NOTE: Switches 4-7 on SW-1 and switches 3-7 on SW-2 are spares and
are not used. Leave these switches in the OFF position.

3.2.1

Elevator Shaft Identification

Each MASTER board must be set to identify which elevator shaft that it is controlling (shaft 1, 2, 3, 4,
5, 6, 7 or 8). The shaft setting is set by switch SW-1, switches 1, 2 and 3 (Table 3). The MASTER
board is the board that has 16 VAC power connected to it and is connected to the access control
system elevator terminals and receives weigand data from the access control system. There can
only be one MASTER board per shaft. If there is more than one MASTER board in the system (two
or more elevator shafts), it is very important that these switches be set correctly.

NOTE: SW-1, switches 1, 2 and 3, apply only to the MASTER board. These switches are not
relevant to other 2348-010 boards connected to the MASTER board via the ribbon cable and can be
left in the OFF position.

Master Board Identification SW-1 Switch Settings

Elevator Shaft Number

SW-1

1

2 3 4 5 6 7 8

Switch 1

OFF

ON OFF ON OFF ON OFF ON

Switch 2

OFF

OFF ON ON OFF OFF ON ON

Switch 3

OFF

OFF OFF OFF ON ON ON ON

Table 3

3.2.2 Floor

Identification

Each of the 2348-010 elevator control boards connected to the system must be set to identify which
floors that the board will control in the shaft that it is in. The floor setting is set by switch SW-2,
switches 1 and 2 (Table 4.).

Floor Identification SW-2 Switch Settings

Floors

SW-2

1-16

17-32 33-48 49-64

Switch 1

OFF

ON OFF ON

Switch 2

OFF

OFF ON ON

Table 4

Page 16

2348-065-E-10-11

Advertising