3 appendix – DoorKing 2348 Elevator Control User Manual

Page 37

Advertising
background image

6.3 Appendix

We strongly recommend that all wiring connections made from the 2348-010 Elevator Control board
to the Elevator Control Panel be marked and labeled. The charts on the following pages should be
completed for written documentation of the wiring interface. An example is shown below.

Be sure that all wires are labeled with a wire number or are color coded. Wire numbers should be
used in large systems because of the number of wires that are required. The wire ID numbers listed
in the Example below were created using the guidelines in Table 5.

1

st

Number

2

nd

Number

3

rd

Number

4

th

Number

The shaft number that
the wire pertains to.

The board number that
the wire pertains to.

Terminal number that
the wire connects to.

The floor number that
the wire controls.

1 1 37

17

Table 5

Shaft 1 – Board 1 (Master)

Shaft 1 – Board 2

Relay No.

Board

Terminals

Floor No.

Wire ID

Relay No.

Board

Terminals

Floor No.

Wire ID

37 1-1-37-17 37 1-2-37-33

16

38

17

1-1-38-17

16

38

33

1-2-38-33

39 1-1-39-16 39 1-2-39-32

15

40

16

1-1-40-16

15

40

32

1-2-40-32

41 1-1-41-15 41 1-2-41-31

14

42

15

1-1-42-15

14

42

31

1-2-42-31

43 1-1-43-14 43 1-2-43-30

13

44

14

1-1-44-14

13

44

30

1-2-44-30

45 1-1-45-12 45 1-2-45-29

12

46

12

1-1-46-12

12

46

29

1-2-46-29

Example

2348-065-E-10-11

Page

37

Advertising