Avaya G350 Manager User Guide

137

Port Redundancy

To configure the device’s port redundancy configuration:

1. Enter an amount in the

Switch Over

field.

2. Select one of the

Switch Back

option buttons.

3. If you selected

After

x

sec

, enter the number of seconds for the

switch back in the

After

x

sec

field.

4. Update the device. For more information on updating the device,

refer to

“Updating the Device” on page 145

.

Secondary

The secondary port of the port redundancy
pair.

Switch Over

The minimum time between switching
between the ports in a port redundancy pair.

Switch Back

The amount of time after the primary port
link is reestablished after which the primary
port takes over from the secondary port.
Possible values include:

Disabled - The primary port does not

take over from the secondary port.

Immediately - The primary port takes

over from the secondary port as soon as
the primary port link is reestablished.

After x sec- The primary port takes over

from the secondary port x seconds after
the primary port link is reestablished.

Table 11-1. Port Redundancy Fields(Continued)