AeGIS 7000P 

Page 23 

Chapter 5

TROUBLE SHOOTING GUIDE

AUDIO PROBLEMS

No audio on key(s) press

1. Turn the system’s power off and on
2. Check the speaker and microphone

connection, check for broken wires.

3. Disconnect the microphone and speaker

connector then check the speaker’s
impedance, must read between 18-24 ohms

No dial tone

1. Turn the system’s power off and on
2. Check the phone line for dial tone. Must check

at the end of the phone cord.

3. Disconnect the microphone and speaker

connector then check the speaker’s
impedance, must read between 18-24 ohms

Tenant can’t hear from the system

1. Turn the system’s power off and on
2. Check the speaker and microphone

connection, check for broken wires

Visitor can’t hear tenant

1. Turn the system’s power off and on
2. Check the speaker and microphone

connection, check for broken wires.

3. Disconnect the microphone and speaker

connector then check the speaker’s
impedance, must read between 18-24 ohms

DISPLAY PROBLEMS

Display shows non-readable characters

1. Turn the system’s power off and on
2. Erase the memory to factory default, see

function code 50, p18.

Display shows blank

1. Turn the system’s power off and on
2. If this is a new installation, turn the system

power OFF immediately. LCD’s ribbon
connection may be incorrect. Call our technical
department 1-888-678-7224

3. Adjust the LCD’s intensity, see figure 2.1 p11
4. Possibility is bad display

Displays shows 8-square blocks

1. Turn the system’s power off and on
2. Turn down the LCD’s contrast, see figure 2.1

p11

3. Possibility is bad main board

Display is hard to read

1. Turn the system’s power off and on
2. Turn up the LCD’s contrast, see figure 2.1 p11
3. Low temperature may cause this issue, install

a heater pad (AHP5)

COMMUNICATION PROBLEMS