12

en

The motor protection filter may be ordered from the after-
sales service. Replacement part number: Please add part
number 608784

Cleaning the washable micro filter*

Figure
Ⅲ Unlatch the twin cylinders and open them forwards.

(See fig. 20)

Ⅲ Remove the dust container from the appliance

(see fig. 21).

Ⅲ Open the exhaust filter cover as far as possible in the

direction of the arrow. The cover engages in this position.

Ⅲ Remove the micro filter.

Figure
Ⅲ Clean the micro filter by knocking out the dirt.
Ⅲ If the micro filter is very dirty, it should be washed (by

hand or in the washing machine at 40°C).

Ⅲ Replace the micro filter.
Ⅲ Close the exhaust filter cover.

Insert the dust container into the appliance.
Fold the dual separator back into position making sure
that it engages.(See fig. 23)

!

Attention: The filter must be completely dry before it
is refitted in order to ensure that it functions correctly
and to prevent the formation of odours or bacteria.

A replacement washable micro filter can be ordered from
After Sales.
Replacement part number: 427226

Replacing the micro active carbon filter*

Figure
Ⅲ Unlatch the twin cylinders and open them forwards.

(See fig. 20)

Ⅲ Remove the dust container from the appliance.

(see fig. 21)

Ⅲ Open the exhaust filter cover as far as possible in the

direction of the arrow. The cover engages in this position.
(See fig. 24)

Ⅲ Remove and dispose of the micro active carbon filter.
Ⅲ Fit a new filter (BBZ192MAF )
Ⅲ Close the exhaust filter cover.

Insert the dust container into the appliance.
Fold the dual separator back into position making sure
that it engages. (See fig. 23)

Replacing the HEPA filter*

Figure
Ⅲ Unlatch the twin cylinders and open them forwards.

(See fig. 20)

Ⅲ Remove the dust container from the appliance.

(see fig. 21).

29

28

27

26

Ⅲ Open the exhaust filter cover as far as possible in the

direction of the arrow. The cover engages in this position
(see fig. 24).

Ⅲ Remove and dispose of the HEPA filter.
Ⅲ Fit a new filter (BBZ153HFB ).
Ⅲ Close the exhaust filter cover.

Insert the dust container into the appliance.
Fold the dual separator back into position making sure
that it engages. (see fig. 23).

Cleaning the twin cylinders

Figure
Ⅲ Use the release button (1) to unlatch the twin cylinders

and open them forwards (see fig. 20).

Ⅲ Turn the cylinder cover as shown to remove from the

appliance.

Ⅲ Clean the cylinder and cover.

Figure
Ⅲ Replace the cylinder cover and lock it into place by

turning in the direction of the arrow (please make sure
that you replace the one marked with an "L" on the left
hand side and the one marked with an "R" on the right
hand side).

Ⅲ Push the twin cylinders back into position (effectively

closing the vacuum cleaner), making sure that they
engage (you will here a positive click) (see fig. 23).

!

Attention: The inside of the twin cylinders may

become scratched with use and start to look
opaque.This does not, however, affect the
performance of the vacuum cleaner in any way, i.e. it
will continue to function as normal.

Care

Always switch off the vacuum cleaner and disconnect the
power cord from the mains before cleaning the appliance.
The vacuum cleaner and plastic accessories can be
cleaned with a commercial plastic cleaner.

!

Do not use a scourer, glass-cleaning agent or all-
purpose cleaning product. Never immerse the
vacuum cleaner in water.

The dust compartment can, if necessary, be cleaned with a
second vacuum cleaner or simply wiped with a dry cloth or
dusting brush.

Subject to technical modifications.