What kind of dirt can be vacuumed up using the
vacuum cleaner?
All kinds of household dirt can be vacuumed up using the
BX3. When vacuuming fine particles, note that the
particulate filter cartridge and fluff filter must be cleaned at
regular intervals to guarantee the optimum function of the
appliance.

Should the dust container be emptied after each use of
the vacuum cleaner?
The dust container should be emptied after each use for
hygienic reasons, or at the latest when the maximum level
(see the mark) is reached.

How often should the particle filter be cleaned/rinsed?
Ideally, the particle filter should be cleaned after each use,
especially after vacuuming fine particles, either by tapping
it or rinsing it, depending on how dirty it is.
The particulate filter cartridge and fluff filter must be
cleaned once the maximum level (see the mark) has been
reached, if not before.

How often should the washable micro-exhaust
filter/motor protection filter be cleaned/rinsed through?
If your vacuum cleaner is equipped with a washable micro-
exhaust filter/motor protection filter, it should be cleaned
regularly for hygienic reasons by tapping it, and must be
rinsed through at least once every three months.

How often should I replace the HEPA filter?
If your vacuum cleaner is equipped with a HEPA exhaust
filter, this should be replaced if it is very dirty and at least
once a year.

What is the best way to transport my vacuum cleaner?
The BX3 can be transported easily using the ergonomic
carrying handle, e.g. for vacuuming the stairs. It is best to
hold/carry the tube with the floor tool in the other hand.

Frequently asked questions

Troubleshooting small problems

Problem
Suction power becomes
noticeably weaker

Bottom flap of the dust
container does not close

Cause
The particulate filter /
motor protection filter is
very dirty

The HEPA filter is very
dirty
The floor tool is blocked
The telescopic tube is
blocked
The hose/hand grip is
blocked
One or both of the twin
cylinders are blocked

The bottom flap
is soiled

Solution
Clean the particulate filter cartridge, motor protection filter and
fluff filter by tapping out the dust or rinsing.

Caution: after rin-

sing, only reinsert the particulate filter cartridge, motor protec-
tion filter and fluff filter back into the appliance once they are
completely dry.

Replace the HEPA filter.

Clean the nozzle, e.g. using a crevice nozzle
Push the telescopic tube together,
loosen and remove the blockage
Separate the hose from the vacuum cleaner and hand grip
Loosen and remove the blockage
Take off the relevant cylinder cover, remove the blockage, clean
with a dry or damp cloth if necessary

Clean the bottom flap, e.g. with a damp
or dry cloth