Problem

Cause

Remedy

LED

D

flashes.

The water tank is not

correctly installed or the

filter is worn.

Correctly install the water tank. If

the LED continues to flash, install

a new filter and rinse, see chapter

“Water filter”.

Carbonated water in the

water tank.

Fill the water tank with fresh tap

water.

The coffee grounds are

not compact and are too

wet.

The grind setting is too

fine or too coarse, or not

enough ground coffee has

been used.

Adjust the grinding unit to a coarser

or finer setting, or use 2 level

measuring spoons of ground coffee.

LED

I

flashes.

Brewing unit (5) is soiled.

Cleaning the brewing unit (5).

Too much pre­ground

coffee in the brewing

unit (5).

Clean the brewing unit (5). Put in

no more than 2 level measuring

spoons of ground coffee.

The brewing unit

mechanism is stiff.

Remove and clean the brewing

unit, see “Maintenance and daily

cleaning”.

Brewing unit (5) is missing

or has not been detected.

Switch off the appliance with the

brewing unit (5) in place, wait

three seconds and switch on the

appliance again.

Coffee or milk froth qual­

ity varies widely.

Build­up of limescale in the

appliance.

Descale the appliance as described

in the instructions.

Water dripped onto the

inner floor of the appli­

ance when the drip tray

(8) was removed.

Drip tray (8) removed too

soon.

Wait a few seconds after the

last drink was dispensed before

removing the drip tray (8).

The default settings have

been changed and need

to be reset.

Some settings have been

made that are no longer

required.

Press the power on/off button

O / I

(9) to switch off the appliance.

Press and hold the service button

(12) and the steam button (11) and

press the power on/off button

O / I

(9) to switch on the appliance. Then

press the start button (10) to con­

firm. The default settings are reset.

LEDs

flash.

The appliance has a fault. Please contact the hotline.

LEDs

flash.

Incorrect voltage.

Operate the appliance at

220 V­240 V only.

LEDs

flash.

The ambient temperature

is too cold.

Operate the appliance at

temperatures > 5° C.