SECTION 2

HPN-IOM-2014-0416

INSTALLATION

2-19

!

WARNING

All information in this manual is for
reference and guidance purposes,
and does not substitute for required
professional training, conduct,
and strict adherence to applicable
jurisdictional/professional codes and
regulations.

Non-Fulton product information is for
reference purposes only. No Fulton
document may substitute for full
review of documentation available
from the component manufacturer.

system must be used.

6. Field-install the liquid level switch (supplied and shipped with the unit).

This must be wired to the control panel.

7. Ensure test connections are accurate. The high and low level test

connections are 1/2” NPT, and are located on the end of the tank opposite
the inlet. The low level is on the center line of the expansion tank, the high
level is next to it, slightly off center. The high level rises up from the bottom
of the tank and ends 4” (102 mm) below the top; the low level rises 2” (51
mm) from the bottom of the tank.

8. Both the high and low level connections should be piped to a safe

catchment. Valves should be installed in these lines at the catch tank.
Installation of the valves should be accomplished in such a manner that
any fl ow will be visible when the valves are open.

9. Flow from the high level test connection indicates a tank that is too full; no

fl ow from the low level test connection indicates too little fl uid.

10. There is a 300 #, raised face, fl anged drain on the bottom of the thermal

buff er section, for the purpose of draining the tank when necessary. This
should be piped with a valve in the line, to a safe catchment. The valve
specifi cations outlined above apply to this valve as well.

3/8” NPT BARRIER OIL

FILL-MECH. SEAL ONLY

3/8” NPT BEARING GREASE

RELIEF AND LIP SEAL

FAILURE DETECTION

1/8” NPT VENT

1/8” NPT

GREASE FITTING

1/2” NPT CASING DRAIN

WHEN SPECIFIED

1/2” NPT DISCHARGE

GAUGE CONNECTION

WHEN SPECIFIED

DISCHARGE

SUCTION

1/4” X 1/8”

KEYWAY

PUMPAGE

LEAK DETECTION

MECH. SEAL ONLY

FIGURE 6 - TYPICAL AIR COOLED PUMP

FIGURE 7 - TYPICAL WATER COOLED PUMP