4.7.3 Bank Select Table

SEQ OUT 4

DATA 7

SEQ OUT 3

DATA 6

SEQ OUT 2

DATA 5

These four signals will output, as
appropriate, when the fastening sequence
reaches a step that has an [OUT] out port
command inserted. Used to provide
sequence operation status out to the PLC.

SEQ OUT 1

DATA 4

SPARE

DATA 3

SPARE

DATA 2

SPARE

DATA 1

Outputs when System is in Program mode.

PROGRAM

DATA 0

ON

OFF

2

SEQUENCE 2

DATA 7

SEQUENCE 1

DATA 6

Output confirmation of SEQUENCE SELECT
0~2 (Pins 9~11) input selections.

SEQUENCE 0

DATA 5

Output after a START signal is received, and
active until the fastening cycle is complete
and the READY signal is output.

BUSY

DATA 4

Output when the system is in READY
condition. Indicates system is ready to
operate, and inputs are enabled. This signal
is inactive (off) when the BUSY output is
active (on).

READY

DATA 3

Output when an Abnormal condition occurs,
this signal indicates that the System has
detected an internal fault, and can no longer
proceed. Details regarding an Abnormal
condition may be output to an Axis Unit
display, if relevant, or out to the System
monitor. An Abnormal condition must be
corrected before the System will resume
normal operation.

ABNORMAL

DATA 2

Output when the fastening result is a
ACCEPT. Indicates all spindles are within
fastening limits. This output remains active
until the START signal or RESET signal is
input.

ACCEPT

DATA 1

Output when the fastening result is a
REJECT. Indicates one (1) or more spindles
has failed fastening limits. This output
remains active until the START signal or
RESET signal is input.

REJECT

DATA 0

OFF

OFF

1

DESCRIPTION

NAME OF

SIGNAL

BANK DATA

PINS 23~30

0

PIN 21

1

PIN 22

BANK

#

Chapter 4: System Setup and Wiring

User Console Version A3.53

Page 4-16