Plc / main controller unit bank data – FEC AFC1200 User Manual

Page 17

Advertising
background image

)(& ,QF

HEAD D REJ.

DATA 7

HEAD C REJ.

DATA 6

HEAD B REJ.

DATA 5

These four signals will output, as
appropriate, when a reject has been
detected for the heads (groups of spindles)
designated A, B, C or D (on the Machine
Configuration screen).

HEAD A REJ.

DATA 4

HEAD D ABN.

DATA 3

HEAD C ABN.

DATA 2

HEAD B ABN.

DATA 1

These four signals will output, as
appropriate, when an Abnormal condition
has been detected for the heads (groups of
spindles) designated A, B, C and D (on the
Machine Configuration screen).

HEAD A ABN.

DATA 0

ON

ON

4

HEAD D END

DATA 7

HEAD C END

DATA 6

HEAD B END

DATA 5

These four signals will output, as
appropriate, upon completion of each
fastening cycle for the heads (groups of
spindles) designated A, B, C and D (on the
Machine Configuration screen).

HEAD A END

DATA 4

HEAD D BUSY

DATA 3

HEAD C BUSY

DATA 2

HEAD B BUSY

DATA 1

These four signals will output, as
appropriate, during each fastening cycle for
the heads (groups of spindles) designated A,
B, C and D (on the Machine Configuration
screen).

HEAD A BUSY

DATA 0

OFF

ON

3

DESCRIPTION

NAME OF

SIGNAL

BANK DATA

PINS 23~30

0

PIN 21

1

PIN 22

BANK

#

PLC / MAIN CONTROLLER UNIT BANK DATA

BANK

SELECT

INPUT

Chapter 4: System Setup and Wiring

User Console Version A3.53

Page 4-17