Plc / main controller unit bank data – FEC AFC1200 User Manual
Page 17

)(& ,QF
HEAD D REJ.
DATA 7
HEAD C REJ.
DATA 6
HEAD B REJ.
DATA 5
These four signals will output, as
appropriate, when a reject has been
detected for the heads (groups of spindles)
designated A, B, C or D (on the Machine
Configuration screen).
HEAD A REJ.
DATA 4
HEAD D ABN.
DATA 3
HEAD C ABN.
DATA 2
HEAD B ABN.
DATA 1
These four signals will output, as
appropriate, when an Abnormal condition
has been detected for the heads (groups of
spindles) designated A, B, C and D (on the
Machine Configuration screen).
HEAD A ABN.
DATA 0
ON
ON
4
HEAD D END
DATA 7
HEAD C END
DATA 6
HEAD B END
DATA 5
These four signals will output, as
appropriate, upon completion of each
fastening cycle for the heads (groups of
spindles) designated A, B, C and D (on the
Machine Configuration screen).
HEAD A END
DATA 4
HEAD D BUSY
DATA 3
HEAD C BUSY
DATA 2
HEAD B BUSY
DATA 1
These four signals will output, as
appropriate, during each fastening cycle for
the heads (groups of spindles) designated A,
B, C and D (on the Machine Configuration
screen).
HEAD A BUSY
DATA 0
OFF
ON
3
DESCRIPTION
NAME OF
SIGNAL
BANK DATA
PINS 23~30
0
PIN 21
1
PIN 22
BANK
#
PLC / MAIN CONTROLLER UNIT BANK DATA
BANK
SELECT
INPUT
Chapter 4: System Setup and Wiring
User Console Version A3.53