FEC AFC1200 User Manual

Page 20

Advertising
background image

)(& ,QF

D1 - Tool/Servo Mismatch

(Abnormal will clear when the tool and Axis Unit are properly matched):

<Check Items>

1. Verify the correct tool is being used for the application. (Refer to Section 2.5)

2. Determine which Axis Unit type is required to operate the tool. (Refer to Section 2.4)

3. Replace components as required.

D7 - overload

(Abnormal will clear after depressing the RESet switch):

<CHECK ITEMS>

1. Check the SET PARAMETER screens and verify that the settings do not result in a Duty

Cycle higher than 50%, and that the resultant cycle time is not less than 12 seconds.

2. Check the connected Axis Units for any abnormal indications. If all spindles appear to be

affected, the problem is likely to be found in another System component.

3. If the problem appears to be a common fault, verify correct input power to the Axis Units.

4. if the problem affects only a single spindle, check the affected spindle for binding and

excessive prevailing torque. If either condition is found, isolate and correct the cause.

5. If no binding or excessive prevailing torque is found, verify correct Axis Unit input voltage

and ensure that the power cable is properly connected.

6. If problem still exists, replace the affected Axis Unit. (Refer to Section 8.3.3)

7. If problem still exists, replace the affected tool. (Refer to Section 8.3.4)

Chapter 9: Troubleshooting

Page 9-20

Advertising