9.2.3 FASTENING

<ERROR DESCRIPTION>

AN attempt was made to change the pREset data during the fastening process.

<CHECK ITEMS>

1. Verify that the Machine is not busy performing a fastening cycle.

2. Place the RUN / PROGRAM switch into the Program position. Enter the desired data,

then place the switch back into the Run position.

3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.

4. Confirm that the ISA Main Unit input power remains constantly within specifications:

200~230 VAC +/- 10%, 50/60 Hz, single phase.

5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.

6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)

9.2.4 UPLOAD ERROR

<ERROR DESCRIPTION>

FASTening has not been performed, or the data that has been collected cannot be
processed.

<CHECK ITEMS>

1. A minimum of 7 fastening cycles is required for the statistical analysis data calculation.

2. THE System must be cycled at least once for a fastening torque curve to be displayed.

3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.

4. Confirm that the ISA Main Unit input power remains constantly within specifications:

200~230 VAC +/- 10%, 50/60 Hz, single phase.

5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.

6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)

9.2.5 NO UPlOAD DATA

<ERROR DESCRIPTION>

SPecified data does not exist for selected screen, or the Processor PCB cannot access it
from the Multi2 PCB.

<CHECK ITEMS>

1. ENTEr the preset data required for the specified screen.

2. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.

3. Confirm that the ISA Main Unit input power remains constantly within specifications:

200~230 VAC +/- 10%, 50/60 Hz, single phase.

4. Verify that the ISA Main Unit power cable is free from damage and is properly connected.

5. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)