3. OPERATION

3.1 Instrument Description

1) Capacitive pick-up
2) Flexible probe
3) Protective rubber holster
4) LCD Display
5) Power ON/OFF / Reset button
6) Secondary Function / Capture button
7) Ignition System button
8) Main Function / Calibrate button
9) Engine Cycles button

3.2 LCD Display

3.2.1 LCD Display description

Fig. 1 - Instrument description

Multisystem Ignition Analyzer

Ignition

System

Function

General

Technologies

Corp.

Made in Canada

Reset

Engine

Cycles

SmarTach

+COP

Peak Voltage

Burn

time

Function

5

Secondary

Main

Calibrate

Capture

Calibrate

3

4

5

7

9

6

8

1

2

C7

Burn Time

Cycles

mS

KVolt

Spark

Fig. 2 - LCD Display

Burn Time

Cycles

mS

Spark

KVolt

Ignition System

Secondary display A
Secondary display B

Function / measurement

units

Number of cycles

Low battery indicator

Spark detected

Secondary display

function

Main display

3.2.2 Low battery indicator
The low battery symbol ‘

‘ indicates the battery voltage is below the minimum

recommended and it needs to be replaced with a new battery.
Notes:
• If the battery voltage is low, but still allows for the operation of the instrument, the low

battery indicator will turn and stay on until the battery is replaced with a new one.

• If the unit turns off immediately after being turned on, it indicates that battery

voltage is below the absolute minimum, and the battery should be replaced to prevent

malfunction.

3.2.3 Number of Cycles
Displays the number of cycles (strokes) selected: 2, 4 or DIS.

3.2.3 Ignition System
Displays the ignition system selected for the measurement: ‘

SPW’ for Spark Plug Wire,

and ‘

COP’ for Coil on Plug and Coil near Plug

3.2.4 Spark Detected

A flashing high voltage symbol ‘

‘ indicates that sparks are being detected in the ignition

system.

3.2.5 Secondary display A
Depending on the setting chosen by pressing the ‘Secondary Function / Capture’

button, it displays maximum readings, RPM or spark KVolt with measurement units

and/or function selected.

3.2.6 Secondary display B
Depending on the setting chosen by pressing the ‘Secondary Function / Capture’ button,

it displays minimum readings, RPM or spark burn time with measurement units and/or

function selected.
Note: RPM measurements in the secondary displays, are shown with the last digit

rounded to ‘0’

3.2.7 Main display
It is the main display, and it can be set to show engine RPM, spark KVolt or spark burn

time by pressing the ‘Main Function / Calibrate’ button.

3.2.8 Functions and measurement units

Displays the measurement units and/or function of the main display. The selected

function with measurement units are displayed as follows:

Display

Function

Measurement units

RPM

Tachometer

RPM (Revolutions per minute)

Burn Time mS

Spark plug burn time

mS (Milliseconds)

Spark KVolt

Spark plug peak voltage

KVolt ( 1000 x Volt)

Advertising