3 buttons description and operation – General Technologies TA500 SmarTach+COP : Multisystem Engine Analyser User Manual

Page 4

Advertising
background image

Page 6

Page 5

3.3 Buttons description and operation

3.3.1 Power ON/OFF and Reset button

• When the instrument is OFF, to turn it ON press and hold the ‘Power ON/OFF

/ Reset’ button until the unit turns on (in approximately 1 second).

• When the instrument is ON, to turn it OFF press and hold the ‘Power ON/OFF

/ Reset’ button until the display turns OFF (in approximately 3 seconds).

• When the instrument is ON, press momentarily the ‘Power ON/OFF / Reset

button to reset the Maximum and Minimum and capture values.

Note: To extend battery life, the TA500 will automatically turn OFF after 3 minutes

of being idle (i.e. no button pressed and no input signal). Turning the unit off

manually, when not in use will prolong battery life.

3.3.2 Ignition System button

• Press the ‘Ignition System’ button to select the ignition system measuring

mode that matches the ignition system used in the engine being diagnosed,

as explained below. The selected setting will be shown on the display.

SPW (Spark Plug Wire): Use this setting for all ignition systems equipped

with high voltage spark plug wires (e.g.: Conventional distributor, magneto,

distributorless or waste spark ignition systems).

COP (Coil On Plug): Use this setting for ignition systems in which the ignition

coil is mounted near or directly on top of the spark plug.

3.3.3 Engine Cycles button

Engine

Cycles

• Press the ‘Engine Cycles’ button to select the number of cycles for the engine

under measurement. Each time the button is pressed the number of cycles

will change between 2 cycles, 4 cycles, and DIS settings. The selected setting

will show on the display.

• For

SPW (Spark Plug Wire) measurements mode, it can be set to : 2 or 4

cycles or DIS (Distributorless or waste spark ignition system).

• For

COP (Coil on Plug) measurement mode, it can be set to: 2 or 4 cycles.

3.3.4 Main Function / Calibrate button

• Press this button to change which measurement is shown in the main (large)

display. There are three measurements to choose from: RPM, spark burn

time, and spark KVolt. Every time this button is pressed momentarily the

measurement changes from one function to the next.

• Press and hold this button for three seconds to start the automatic calibration of

the unit to the

COP module type being measured. While calibrating, the display

will flash “CAL” and will return to normal after the procedure is completed (in

about 3 seconds). Calibration is disable when in

SPW mode.

MAX

MIN

Cycles

Burn

Time

Cycles

KVolt

Peak Voltage

Burn

Time

MAX

MIN

Cycles

KVolt

Spark

Burn Time

Cycles

mS

Spark

MAX

MIN

Cycles

Burn Time

Cycles

KVolt

mS

Peak Voltage

KVolt

Function

Main

Calibrate

Calibrate

Function

Secondary

Capture

Function

Secondary

Capture

Function

Secondary

Capture

Function

Main

Calibrate

Calibrate

3.3.5 Secondary Function / Capture button

• Press this button momentarily to change what is displayed in the two

secondary displays. The are two possible choices: the two measurements

not shown in the main display or the Maximum and Minimum readings of the

main display.

• Pressing and holding this button for three seconds enables ‘Capture mode’,

which measures and holds the maximum readings. To exit this mode press

the ‘Secondary Function / Capture’ button momentarily again.

3.3.6 Main and Secondary Functions display combinations

Fig. 3 - Examples of Main and Secondary Functions combinations

Advertising