3.5 Additional functions

3.5.1 Minimum and Maximum functions (For COP and SPW modes)
The TA500 maintains a continuous record of the minimum and maximum readings of the

function currently selected.

1- To display the Minimum and Maximum readings of the main display, if not already

selected press ‘Secondary Function / Capture’ button momentarily.

2- To reset the Minimum and Maximum readings, press the ‘Power On/Off / Reset’ button

momentarily. These values are also reset when turning the unit on.

Note:
• For the tachometer function (RPM) all Minimum and Maximum readings on the

secondary displays are shown with the last digit rounded to “0”.

3.5.2 Spark KVolt calibration function (For COP mode only)
The TA500 requires the user to calibrate the instrument in order to measure spark

KVolt in Coil on Plug and Coil near Plug ignition systems. This calibration uses the

measurement values obtained during the procedure to find the optimal measuring

parameters or a particular type of ignition module, and compensates for differences in

waveform and signal strength.
• Once the TA500 has been calibrated on one of the ignition modules of the engine

being diagnosed, all the subsequent measurement of spark KVolt will be relative to the

calibration value.

• To calibrate the TA500, follow the procedure as described in ‘3.4.2 Measuring Coil on

Plug and Coil near Plug ignition systems’.

Page 9

3.4.2 Spark plug wire ignition systems

1- Turn the instrument on.
2- If not already in

SPW (Spark Plug Wire) mode, select it by pressing the ‘Ignition System’

button.

3- Select the number of cycles for the engine under measurement by pressing the ‘Engine

Cycles’ button repeatedly until the display shows the correct setting.

4- Select the measurement to show in the main display: RPM, spark burn time or

spark KVolt.

5- Select the mode for the secondary display: Minimum and Maximum of the main display

or the complementary measurements.

6- Place the capacitive pickup over one of the spark plug wires, and proceed to read the

measurement on the display.

Spark plug wire

Spark plug wire

Capacitive pick-up at 90°

Capacitive pick-up parallel

Fig. 6 - Capacitive pick-up on spark plug wire

Page 10

Important:
• In order to obtain consistent results when measuring Spark KVolt on spark plug wires,

the position of the capacitive pick-up relative to the spark plug wire should be the

same for every measurement.

• An easy way to obtain consistent measurements, is to position the capacitive

pick-up either at 90° or parallel to the spark plug wire (Fig 5), and then repeat the

same positioning for every spark plug wire

• Spark burn time and RPM measurements are not sensitive to the exact position of

the capacitive pick-up relative to the spark plug wire, but it has to be placed so the

instrument is capable of detecting the signal.

• When several spark plug wires are routed or bunched close together, the

capacitive pick-up may receive signals from several wires at the same time,

which could cause erroneous measurements. In these situations it may be

necessary to separate the wire under measurement from the others, in order to reduce

interference and obtain an accurate measurement.

Notes:
• Immediately after calibration, the TA500 will display a baseline value of “10.0 Spark

KVolt” by default. All the spark KVolt measurements obtained thereafter would be

relatives to the (value) module used for calibration.

• Calibration does not have any effect on spark burn time or RPM measured values

(these are absolute).

• If the TA500 is calibrated again, the Spark KVolt values obtained before and after

calibration may not be comparable.

• If not calibrated, the TA500 may show a false ‘0.0 Spark KVolt’ reading when

measuring spark KVolt on Coil on Plug and Coil near Plug systems.

Fig. 7 - Display during calibration

Burn Time

Cycles

Peak

G7

G7

mS

Flashing letters