Print data strings – Fairbanks NexWeigh User Manual
Page 35
Section 5: Serial I/O
04/14
35
51216 -- Rev. 6
5.3. PRINT DATA STRINGS
Serial Data String – Demand Mode:
Gross
<WWWWWWW> <SP> <lb><SP><GR><CR><LF>
Then, (if applicable)
Tare
<WWWWWWW> <SP> <lb><SP><TA><CR><LF>
Then, (if applicable)
Net
<WWWWWWW> <SP> <lb><SP><NT><CR><LF>
Then, (if applicable)
Time
<HH><:><MM><:><SS><SP><AM><CR><LF>
Then, (if applicable)
Date
<MM></><DD></><YY><CR><LF>
Then, (if applicable)
ID
<Scale><SP><Id><SP><##><CR><LF>
<CR><LF>
Serial Data String – Continuous Mode:
Gross (Stable) <WWWWWWW> <SP> <lb><SP><GR><CR><LF><EOT>
<WWWWWWW>
Up to 6 places with no decimal, up to 7 places with a decimal point
<SP>
Space
<lb>
Unit of measure could be: lb, kg, gr, oz
<GR> or <gr>
Upper case indicates stable weight, lower case unstable weight
<TA>
Tare weight
<NT> or <nt>
Net weight (upper case = stable, lower case = unstable)
<CR>
Carriage return
<LF>
Line feed
<EOT>
End of text
Time
HH = Hour, MM = Minute, SS = Seconds, and AM or PM
Date
MM = Month, DD = Day, YY = last 2 digits of the year (20YY)
ID
“Scale Id” and ## = 2 digits for the actual scale ID