6.3.5. Weight Accumulation, Continued

J. Accumulation Notes.

1. No units switching is allowed if Accumulation is currently activated, or if an

accumulation has been stored and not cleared. The message NoUntS will be
displayed if

UNITS

is pressed.

2. On power up or return from Program mode or Checkweigh Setup mode, if an

accumulation has been stored in units other than Primary Units (PU in config
menu), the accumulation units will be automatically selected.

3. If the accumulation units are no longer enabled on power up or return from

Program mode or Checkweigh Setup mode, the accumulated values will be
cleared and Primary Units will be selected.

6.3.6. Peak Hold Weighing

A. Enabling PEAK HOLD

1. Press and hold

OVER/UNDER/NEXT

until display indicates ChEc.

2. Press

OVER/UNDER/NEXT

to display HoLd.

3. Press

PROGRAM/ENTER

to display HoLd X, where X is either Y or n.

4. Press

OVER/UNDER/NEXT

to display HoLd Y if necessary.

NOTE:

The Peak Hold function must not be used with Checkweighing.

5. Press

PROGRAM/ENTER

to display CSAvEd, and returns to weigh mode.

Instrument is now in Peak Hold mode.

B. Operating Peak Hold

1. Press the

1 (one)

button to activate Peak Hold mode. The first three

instruments for UNDER, ACCEPT and OVER will flash indicating Peak Hold is
active. Also the instruments on the

1

,

2

, and

3

buttons will be on.

Advertising