12

7. Install o-ring (item 2). See figure

39.

8. Install impeller shaft (item 6) into
barrier by aligning the flats
on the shaft with the ones in
the barrier. Make sure it is
completely seated. See figure 39.

9. Carefully install the impeller/inner drive assembly (items 4,

4A, 5, 5A) by sliding it over the impeller shaft in the barrier. It is

Figure 39

normal for the impeller /inner drive to pop up a slight amount

due to magnetic forces. See figures 40 and 41.

Figure 40

Figure 41

10. Install the impeller housing (item 1). Make sure the dis

charge is in the correct orientation in relation to pump foot.

Align the shaft in the barrier with the front shaft support in

the impeller housing. Press down to push the impeller/in

ner drive magnet assembly into position. Holding the

impeller housing with one hand, install and finger-tighten

two bolts, lock washers and flat washers (items 12, 13, 14)

in opposite locations. See figure 42.

Figure 42

11. Install the remaining bolts, lock washers and flat washers

finger tight.

12. Tighten all the bolts evenly using a star pattern. Tighten to

20 foot-lbs (27 N-m).

13. Reinstall the pump on the motor/drive magnet following

instructions found in “Assembly, Pumps Without Motors,”

steps 7-10.