Maintenance, Operation – Finish Thompson KC22/32 SERIES User Manual

Page 2

Advertising
background image

2

3. Connect drain hose to water outlet valve.
4. Open inlet and outlet valves, and flush system until pump

is clean (approximately 5 minutes).

MAINTENANCE

DISASSEMBLY

1. Disconnect power. Remove electrical wiring and mounting

bolts to floor or base plate.

2. Close suction and discharge valves, and disconnect piping.
3. Remove bolts, nuts and washers (items 7, 8 and 9). Leave

the 2 housing studs (item 15) in place until the wet end is

removed.

4. Securely clamp or hold motor in place. Remove wet end

assembly by inserting both thumbs into pump suction and

pulling assembly straight out with a quick motion.

WARNING: Components can slam together from strong

magnets. Keep fingers away from area between housing

and motor adapter.

5. Disassemble wet end by removing 2 housing studs and

nuts (items 16) which attach barrier (item 4) to impeller

housing (item 1). Remove and discard o‑ring (item 13).

6. Remove drive magnet assembly by inserting a 3/16" hex

wrench into access hole in side of motor adapter and

loosening 2 set screws (item 5A). Grasp inside of magnet

assembly and pull off of motor shaft.

CAUTION: Strong magnets present. Keep metal objects and

metallic chips/particles away from pump components.

EXAMINATION

1. Check impeller drive bushing (item 3A) and impeller thrust

washer (item 2A). If cracked, chipped or scored, then

replace. Replace if minimum groove height is less than the

minimum height recommended. See Figure 4.

2. Check for loose magnets.

ELECTRICAL

Install motor according to NEC requirements and local electrical

codes.

IMPORTANT: To verify correct motor rotation: (1) Install pump into system.
(2) Fully open suction and discharge valves. (3) Allow fluid to flow into the
pump. Do not allow pump to run dry (PTFE and ceramic bushings cannot be
run dry without damage to pump components). (4) Jog motor (allow it to run
for one or two seconds) and observe rotation of motor fan. Correct rotation is
clockwise as viewed from motor fan. Refer to directional arrow on pump.

OPERATION

START UP

1. This pump must be filled from a flooded suction tank

(gravity) or primed with liquid from an outside source. The

KC22/32 are not self‑priming.

2. Open the inlet (suction) and discharge valves completely

and allow the pump to fill with liquid.

3. Close the discharge valve.
4. Turn the pump on. Slowly open the discharge valve. Adjust

the flow rate and pressure by regulating the discharge

valve. Do not attempt to adjust the flow with the suction

valve.

5. Use of a power monitor is strongly recommended for

pumps with ceramic, PTFE or silicon carbide bushings.

The power monitor will stop the pump and help prevent

damage should the pump run dry. ATEX certified pumps

MUST use a power monitor.

SHUT DOWN

Use the following procedure to shutdown the pump.
1. Slowly close the discharge valve.
2. Turn off the motor.
3. Close the suction valve.

FLUSH SYSTEM

1. Fully close suction and discharge valves.
2. Connect water supply to water inlet valve.

9. The suction valve should be fully open to avoid restricting

suction flow.

IMPORTANT: To protect the pump if prime is lost, use one

of the following: (1 ) pressure switch on the discharge;

(2) vacuum switch on the suction; (3) a power monitor to

monitor motor current.

10. When pumping liquids which may solidify or crystallize, a

flush system should be added to the piping. See Figure 3.

Install water inlet and outlet valves as shown.

Discharge

Valve

Water Inlet

Valve

Suction

Valve

Water Outlet

Valve

Figure 3

.780 MAX.

Diameter

.020 MIN.

Groove Height

Figure 4

IMPELLER DISASSEMBLY

1. To separate impeller body (item 2) from the impeller drive

(item 3), support the body in an arbor press using two 5"

minimum spacer blocks.

2. Insert a 1‑1/2" diameter plastic or wooden shaft into the

impeller eye, and push the drive out of the body. See

Figure 5.

Figure 5

5” MIN.

Support

Advertising