Finish Thompson GP22/32 SERIES User Manual

Page 5

Advertising
background image

5

wArrANTY

Finish Thompson, Inc (manufacturer) warrants this pump product to be

free of defects in materials and workmanship for a period of one year

from date of purchase by original purchaser. If a warranted defect, which

is determined by manufacturer’s inspection, occurs within this period, it

will be repaired or replaced at the manufacturer’s option, provided (1) the

product is submitted with proof of purchase

date and (2) transportation

charges are prepaid to the manufacturer. Liability under this warranty is

expressly limited to repairing or replacing the product of parts thereof

TECH SERVICE 1-800-888-3743

P/N J102611, Rev. 13, 3-26-13

Lit. ID No. FT95-574J

d. Bolt the motor adapter to the motor using the hex-head cap

screws and lock-washers.

e. Double check the alignment of the water connection holes in the

cooling collar.

6. Install the impeller housing.

a. Install the housing cover’s o-ring.

b. Place the impeller housing into position and install the

hardware. Tighten the six hex-head cap screws to 90 in•lbs.

c. Look through the discharge of the pump to verify proper

spacing between the impeller and the housing cover.

TrOuBLeShOOTINg

NO Or INSuFFICIeNT FLOw

1. Pump not primed.
2. Closed valve.
3. Viscosity too high.
4. Air leaks in suction piping.
5. Discharge head higher than anticipated.
6. Suction lift too high or insufficient NPSH. Check also for clogged

suction line.

INSuFFICIeNT PreSSure

1. Air or gasses in liquid.
2. Impeller diameter too small.
3. Discharge head higher than anticipated.

LOSS OF PrIMe

1. Leaking suction line.
2. Foot valve or suction opening not submerged enough.
3. Foot valve too small or leaking.
4. Air or gasses in liquid.
5. Foreign matter in impeller.

exCeSSIve POwer CONSuMPTION

1. Head lower than rating. Excessive flow.
2. Specific gravity or viscosity of liquid is too high.

exCeSSIve vIBrATION

1. Loose piping or bolts.
2. Pump cavitating from improper suction or feed.

Call our toll free Technical Service hot Line, 1-800-888-3743, if you

have any questions regarding product operation or repair.

OrderINg SPAre PArTS

Spare parts can be ordered from your local distributor. Always refer to

pump model number to avoid error.

OTher FTI PrOduCTS

drum Transfer Pumps are available in sanitary construction, stainless

steel, polypropylene and CPVC. Flows to 40 gpm, discharge heads to

80 feet and viscosities to 100,000 cP.
Portable Mixers for turbine mixing and blending handle viscosities to

1,000 cP with gentle, non-vortex circulation. Available in 316 stainless

steel construction.
Sealless Mag drive Centrifugal Pumps in polypropylene and CF PVDF.

Ansi-dimensional mag drives in ETFE lined ductile iron. Flows to 330

gpm and discharge heads to 325 feet. Handle temperatures up to 220°F

(104°C) and have run-dry capability. Mount to standard frame motors.
For further information, contact FTI or your local distributor.

and is in lieu of any other warranties, either expressed or implied. This

warranty does apply only to normal wear of the product or components.

This warranty does not apply to products or parts broken due to, in

whole or in part, accident, overload, abuse, chemical attack, tampering,

or alteration. The warranty does not apply to any other equipment used

or purchased in combination with this product. The manufacturer accepts

no responsibility for product damage or personal injuries sustained when

the product is modified in any way. If this warranty does not apply,

the purchaser shall bear all cost for labor, material and transportation.
Manufacturer shall not be liable for incidental or consequential damages

including, but not limited to process down time, transportation costs,

costs associated with replacement or substitution products, labor costs,

product installation or removal costs, or loss of profit. In any and all

events, manufacturer’s liability shall not exceed the purchase price of

the product and/or accessories.

CheMICAL reACTION dISCLAIMer

The user must exercise primary responsibility in selecting the product’s

materials of construction, which are compatible with the fluid(s) that

come(s) in contact with the product. The user may consult Finish

Thompson, Inc. (manufacturer) and a manufacturer’s representative/

distributor agent to seek a recommendation of the product’s material of

construction that offers the optimum available chemical compatibility.
However neither manufacturer nor agent shall be liable for product

damage or failure, injuries, or any other damage or loss arising out of

a reaction, interaction or any chemical effect that occurs between the

materials of the product’s construction and fluids that come into contact

with the product’s internals.

Advertising