CAUTION: Do not run the pump dry. This could damage the pump. The fluid being transferred by the pump lubricates the

pump. Even short periods of running the pump dry could damage the pump. It is recommended that a run dry protection

device be used.

CAUTION: Do not dead head the pump. Running the pump at zero flow will cause any liquid inside the pump to elevate rapidly

in temperature. This will continue until the boiling point of the liquid is reached. The liquids will flash to vapor, causing the pump

to run dry, and destroy the pump. Run dry protection in the form of a power monitor is recommended.

WARNING: All ATEX compliant pumps must use a power monitor to protect against running dry, closed discharge valve, and

pump decoupling. Any of these conditions could lead to elevated surface temperatures.

CAUTION: Cavitation for an extended period of time can cause pitting and damage on the pump components. Make certain

NPSHa is greater than pump NPSHr.

CAUTION: Water hammer. Rapid changes in the fluid’s velocity can cause large, sudden pressure surges. These pressure

surges can damage the pump, plumbing and instrumentation. Common causes are rapidly closing valves. Check valves on the

suction can also cause water hammer if the liquid has time to reverse direction before the valve closes.

Motor/Electrical

Install the motor according to NEC requirements and local electrical codes. The motor should have overload protection. The use of

a power monitor is highly recommended.
Note: All ATEX certified pumps must use a power monitor.
1. The motor must be installed with flexible conduit in order to allow a minimum of 6” of motor movement so that the pump can

be disassembled.

2. Check all electrical connections with the wiring diagram on the motor. Insure that the voltage, frequency, and horsepower on

the motor comply with the line circuitry.

3. If utilized, check that the power monitor has been properly installed in accordance with the manufacturers directions.
CAUTION: Do not operate the pump to check rotation until the pump is full of liquid.

Pre-Operation Inspection

Prior to the first operation of the pump, perform the following inspections:
WARNING: Lock out power to the driver to prevent accidental motor start-up and physical injury.
1. Insert a screwdriver through the fan cover and rotate the fan. It should move without restrictions.
2. Verify that all flange and hold down bolts are tightened.

Operation

Start-up and Operation

1. This pump must be filled from a flooded suction tank (gravity) or primed with liquid from an outside source. The ULTRAChem

is not self-priming.

2. Ensure that the pump is full of liquid and the inlet (suction) valve is open.
3. Open the discharge valve completely and then close it so that there is no trapped air in the suction and discharge line.
4. After the pump is full of liquid, check that the rotation of the motor/ pump is in the correct direction. This can be achieved by

jogging the motor for approximately 1/2 second. The motor rotation can be observed from the fan end. Correct rotation when

viewed from the fan end is clockwise.

Note: A pump running backwards will pump but at a greatly reduced flow and pressure.

5. Turn the pump on. Slowly open the discharge valve. Check pump for proper flow and pressure, and that pump runs without

excessive noise or vibration.

6. Keep the suction valve in the fully open position. Never use the suction valve to regulate the flow rate. Use the discharge valve

only.
Note:

It is not necessary to jog the motor or adjust the valves on subsequent pump starts provided that the pump and piping

remain full of liquid.