Safety – Finish Thompson PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) User Manual

Page 4

Advertising
background image

3

Safety

1. Introduction

This manual contains all the information needed for the correct installation, use and maintenance of your new Finish Thompson

pump. It should be read and understood by all the personnel involved in installation, operating and servicing of the pump before

it is started.

2. Operator Qualification and Training

The personnel in charge of the installation, the operation, and the maintenance of the pump must be qualified and able to per-

form the operations described in this manual. Finish Thompson, Inc. shall not be held responsible for the training level of

personnel and for the fact that they are not fully aware of the contents of this manual.

3. Safety Instructions

FOR YOUR OWN SAFETY

BEFORE using or servicing your pump, please make sure to wear the proper clothing, eye protection and follow standard safety

procedures when handling corrosive or personally harmful materials.

GENERAL DANGER

ALWAYS use a stainless steel pump tube with an explosion proof electric motor or air motor and static protection kit with

grounded discharge hose when pumping or mixing flammable or combustible material.

ALWAYS use and store the pump and motor in an upright position.

NEVER use in pressurized containers.

ALWAYS use a chemically compatible hose rated for the temperature of the product being pumped.

ALWAYS select the proper o-ring material. Improper material selection could lead to swelling and be a possible source of leaks.

This is the responsibility of the end user.

ALWAYS check the pump for leaks on a regular basis. If leaks are noticed, the pump must be repaired or replaced immediately.

ALWAYS clean the pump on a regular basis to avoid any dust buildup greater than 5mm deep.

ALWAYS check compatibility and temperature range of pump with liquids used. A Chemical Resistance and Material Selection

Guide can be downloaded from our website at www.finishthompson.com.

NEVER run dry.

NEVER use with liquids containing solids that can damage the internals (i.e. metal chips) without optional strainer.

ALWAYS flush unit with water after each use.

ALWAYS store unit upright, i.e. motor above pump, and away from corrosive liquids and vapors.

ALWAYS check bearings for signs of overheating, abnormal noise or other signs of premature failure on a daily basis. Bearings

should be replaced at the first sign of failure.

ALWAYS when using an air motor, use an automatic airline lubricator, moisture trap, and filter in the airline before the motor

(use SAE#10 oil in the lubricator). Adjust lubricator to feed one drop of oil per minute of continuous run time. Do not exceed
80 psi (551 kPa) on M6A and 100 psi (689 kPa) on M6XA. Maximum air consumption: M6A = 27 cfm (47 m3/hr),
M6XA = 30 cfm (49.5 m3/hr).

DANGER: POWER SUPPLY

Refer to instructions in this manual.

4. Noise Level

90 db at a distance of 3 feet (approximately 1 meter).

5. Modifications and Spare Parts

Any changes concerning the service of the pump as originally purchased can be executed only after written approval from

Finish Thompson Inc. It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories. The

use of non-original spare parts or non-approved accessories will void warranty and removes any responsibility on the manufac-

turer’s behalf for any damage caused to people or things.

6. Cleaning

It is highly recommended to flush pumps with clean water or some other neutralizing fluid compatible with pump materials

when done pumping or when switching chemicals.