Safety, Introduction, Specifications – Finish Thompson FM2000 Series User Manual

Page 3: Features

Advertising
background image

Safety

ALWAYS wear protective clothing, eye protection, and follow standard safety procedures when handling
corrosive or personally harmful materials.

NEVER use this flow meter with flammable or combustible liquids.

NEVER use this flow meter in a hazardous environment.

ALWAYS verify chemical compatibility with the flow meter and pump materials of construction before operation.

ALWAYS make sure the pump and hose are properly supported.

ALWAYS use a chemically compatible hose rated for the temperature of the product being pumped.

ALWAYS place pump tube in liquid before starting.

Introduction

Thank you for purchasing an FM-2000 Series electronic flow meter. The FM-2000 Series is designed to measure the flow of a fluid being dis-
pensed from Finish Thompson’s PFP, PFM, & PFV drum pumps. The meter is factory calibrated and displays information on an LCD display. In
addition, the meter can be field calibrated to improve accuracy at a given flow rate. Four AA batteries power the unit for up to one year. There
are options for materials of construction and measurement units
FM-2000 is a rate/totalizer meter – designed to measure and display both the rate of flow and the total flow.

Specifications

Maximum Working Pressure:

35-62 PSIG (2.4 – 4.3 bar)

Maximum Fluid Temperature:

PFM & PFP Models = 160º F (71º C); PFV = 120º F (49º C)

Ambient Temperature Range:

32º to 110ºF / 0º to 43º C

Enclosure:

NEMA 4X (IP56)

Sensor/Paddle/Axle Material:

PVDF

O-ring seals:

Viton

Accuracy:

+/-1% of full-scale rate reading; can be field calibrated

Repeatability:

+/-1% of full-scale rate reading

Power Requirements:

Four standard AAA alkaline batteries (included)

Battery Life Expectancy:

1 year minimum

Maximum Viscosity:

20 cP/mPas

Maximum Specific Gravity:

1.8

Features

• Easy to read eight digit LCD display
• Installs quickly on PFM, PFP, PFV Series pump tubes with supplied fittings
• Factory calibrated; can be field calibrated using front panel touch buttons
• Minimal maintenance required
• Corrosion resistant PVDF sensor with polypropylene or PVDF body, ABS electronics enclosure
• Weather resistant enclosure
• High accuracy· Non-volatile memory stores settings even when batteries are removed

Kit Contents:

• FM-2000 Series Meter
• Flow meter adapter
• Discharge nut
• 1” NPT coupling
• Hose barb adapter

1

Advertising