Always wear protective clothing, eye protection and follow standard safety
procedures when handling corrosive or personally harmful materials.

Never use this pump/motor to pump flammable or combustible material or
operate it in explosion hazard areas.

Always ensure that the pump and hose materials are compatible with liquid
being pumped.

Always ensure that the liquid temperature does not exceed 120°F (50°C).

Always ensure the switch is in the OFF position before connecting the
motor to the electrical supply.

Always use this pump in an upright position; do not allow the motor to
become immersed in liquid.

Never operate unattended. This pump is a hand-held device.

Never allow the pump to run dry. Place in the liquid before starting.

Always make sure the pump and discharge hose are properly supported.

Never use this pump in pressurized containers.

Always flush the pump with water or compatible cleaner after use.

EP SERIES (ECONO PUMP)
OPERATION AND PARTS MANUAL

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

ASSEMBL

ASSEMBL

ASSEMBL

ASSEMBL

ASSEMBLY

Y

Y

Y

Y

·

Unpack the motor and pump from cartons, and check for shipping
damage. If shipping damage is found, save the packaging and notify the
carrier immediately.

·

Remove the two socket head bolts from the head of the pump tube.

·

Place the coupling insert onto the coupling-half of the pump tube.

·

Position the electrical motor handle (the ball valve and the muffler on the
air motor), so it is opposite the pump’s discharge spout. Insert the
bottom of the motor into the head of the pump tube and “jiggle” until the
coupling is seated.

·

Reinsert the two socket head bolts into the pump head and hand tighten
(do not over tighten).

Note: Screws will not insert unless motor is properly seated and posi-
tioned on the pump tube.

·

Install a discharge hose onto the spout [3/4” (20 mm) barbed hose
fitting], and clamp securely.

INTENDED DUTY/USER NOTES

INTENDED DUTY/USER NOTES

INTENDED DUTY/USER NOTES

INTENDED DUTY/USER NOTES

INTENDED DUTY/USER NOTES

The electric motor is intermittent duty (15 minutes on/15 minutes off).

The air motor requires 80 psi @25 cfm and we recommend an in-line filter/
lubrication system for prolonged life.

The pump is designed for transfer of liquids within a temperature range of
40°F (5°C) to 120

o

F (49

o

C). Maximum liquid specific gravity is 1.2,

maximum viscosity is 150 centipoise. Not compatible with liquids
containing abrasives or solids.

Materials of construction (wetted) are:
Polypropylene, PVDF, and PTFE with a 316 stainless steel or alloy 625
shaft.

The electric motor has a thermal overload device. If the overload device
trips, it must be manually reset by removing electrical power (place switch
in OFF position) and allowing the motor to cool to ambient temperature.

Flow performance for electric and air motors is approximately 5 gallons per
minute (19 liters per minute). Performance may vary depending upon the
characteristics of the liquid.

For faster prime and better flow, lift the pump slightly off the bottom of the
container during operation.

The electric motor supply cord cannot be replaced. If the cord is damaged,
the motor should be replaced.

WARRANTY

WARRANTY

WARRANTY

WARRANTY

WARRANTY

Finish Thompson, Inc. (manufacturer) warrants this product to be free of
defects in materials and workmanship for a period of one year from date of
purchase by original purchaser. If a warranted defect, which is determined
by manufacturer’s inspection, occurs within this period, it will be repaired or
replaced at the manufacturer’s option, provided (1) the product is submitted
with proof of purchase date and (2) transportation charges are prepaid to
the manufacturer. Liability under this warranty is expressly limited to
repairing or replacing the product of parts thereof and is in lieu of any other
warranties, either expressed or implied. This warranty does apply only to
normal wear of the product or components. This warranty does not apply to
products or parts broken due to, in whole or in part, accident, overload,
abuse, chemical attack, tampering, or alteration. The manufacturer accepts
no responsibility for product damage or personal injuries sustained when
the product is modified in any way. If this warranty does not apply, the
purchaser shall bear all cost for labor, material and transportation.

Manufacturer shall not be liable for incidental or consequential damages
including, but not limited to process down time, transportation costs, costs
associated with replacement or substitution products, labor costs, product
installation or removal costs, or loss of profit. In any and all events,
manufacturer’s liability shall not exceed the purchase price of the product
and/or accessories.

Please contact the distributor in your area if you experience a problem with
the product. The distributor will then determine if a factory return is
necessary and will contact the factory for a return authorization number.

Call our toll free Technical Service Hot Line, 1-800-888-3743, if you have
any questions regarding product operation or repair.

ORDERING SP

ORDERING SP

ORDERING SP

ORDERING SP

ORDERING SPARE P

ARE P

ARE P

ARE P

ARE PAR

AR

AR

AR

ARTS

TS

TS

TS

TS

Spare parts can be ordered from your local distributor. Always refer to
pump model number to avoid error.

Tech Service: 1-800-888-3743

Part No. J103424, Rev. 5

Literature ID No. FT98-712E

See Finish Thompson’s full range of drum pumps and centrifu-
gal pumps at www.finishthompson.com

Advertising