For models wIth

non-AdjustAble

regulAtors wIth

mAnuAl VAlVes

1. Check that the casting is properly

located as per the diagram and

that the orifice is properly located in

respect to the jet pipe. (Figure 1)

2. Make certain that the manual valves

are turned to the OFF position by

turning them clockwise until they

reach the stop position.

3. Open the cylinder control valve by

turning it counterclockwise as per

the diagram (Figure 2).

4. To light the jet burner, hold a multi-

purpose lighter or paperback match

over the jet pipe as per (Figure

3). Turn the corresponding manual

valve control toward the ON position

until ignition occurs. Turning the

manual valve counterclockwise

increases the gas flow to the burner

and hence the flame size (Figure

2). To light the cast burner, hold

a multipurpose lighter or use a

paperbook match placed above the

casting as per (Figure 4). Turn

the corresponding manual valve

control toward the ON position until

ignition occurs. Turning the manual valve counterclockwise increases the gas flow to the burner

and hence the flame size (Figure 2). When lighting the stove, if ignition does not occur in 3 to

5 seconds, turn the manual valve(s) and cylinder control off. Wait 5 minutes for gas to disperse.

Repeat Procedure.

5. Refer to (Figure 5) for proper flame emission for the jet and cast burners. The casting flame should

be blue and the flame should be emitted from every port in the casting. If not, rotate the air shutter

position until there is a blue flame. Opening the shutter too much will cause the flame to “lift” off

the burner. If there is a yellow flame, or if some ports have no flame, this indicates there may be an

obstruction in the venturi tube or ports. Check the maintenance instructions on page 18 for more

information regarding a yellow flame.

6. Always monitor the flame throughout the cooking process. If at any point in the cooking process

the flame(s) are accidently extinguished, immediately turn the manual valve(s) and cylinder valve

OFF. Wait 5 minutes for gas to disperse and relight the cooker according to the lighting insructions

(#1 - #5) in this section.

neVer put hAnds or FAce dIrectly oVer burner whIle lIghtIng

or whIle the ApplIAnce Is lIt.