No. 2 Process Electric Motor Version - Installation

Ransburg

10

AH-13-01.1

Before attempting to install the equipment, ensure

that all the necessary components are available

(see “Parts Identification” section of this manu-

al). In addition, read all the technical and safety

literature that is provided. If the literature is not

available, contact your local Ransburg Distributor

where the equipment was purchased.

POWER SUPPLY

(Refer to Figure 2)
1. The high voltage power supply MUST be located

at least 6.1 m (20 feet) from the spraying operation.

If a spray booth is used, the power supply may be

located 1.5 m (5 feet) from the nearest opening

and outside the booth .

2. If a line cord is used instead of a permanent

conduit connection, ensure the ground lead is

present on the plug. Ensure that the electrical

outlet is properly wired by using the circuit tes-

ter (20868-00). Attach the green ground wire to

a proven, true earth ground (i.e., water pipe or

electrical conduit).

3. After the power supply is grounded to a suit-

able earth ground, the high voltage cable may

be connected. Prior to connection of the high

voltage cable 15 to 30 ml of 3614-00 (supplied

with applicator ) di-electric oil needs to be added

to the power supply. Refer to figure 3 for illustra-

tion of where the oil should be inserted.

4. Apply a generous amount of LSCH 0009 on

the power supply end of the cable as shown in

figure 3.

5. Attach the female nut of the high voltage ca-

ble to the male threads of the connection of the

power supply.

†

Where the applicator is to be used with-

out a booth, the power supply must located

a minimum of 6.1 m (20 feet) from the target

being sprayed.

†

The target Earth Ground and Power

Supply earth ground must be separate earth

ground connections.

†

Any fluid hose that is are user supplied

must be rated for the maximum pressures

used for this applicator.

FLUID HOSE

(Refer to Figure 4)
Install the fluid filter (Item 5) to the applicator,

then to the fluid delivery hose. Attach one end

of the fluid hose to the adapter (Item 6) (Refer to

figure 4). This adapter has a 3/8-18 NPSM (F)

for attachment to a suitable fluid source. To meet

various length requirements, the hose fitting on

one end has not been attached.

Figure 5 illustrates the assembly procedure for

attaching the loose fitting.

†

The power source wiring and the power

supply connections to it MUST meet all local

fire and electrical code standards and com-

ply with all appropriate local and national

health and safety codes.

†

All power supplies MUST be grounded

to a known true earth ground before any

other connections are made or functions

performed. DO NOT use the power supply

ground wire to ground the target objects (use

LSME4000-00 clamp assembly)!

W A R N I N G

!

W A R N I N G

!