9060 fuse replacement, Ransburg – Ransburg No. 2 Process Handgun Electric Motor User Manual

Page 40

Advertising
background image

No. 2 Process Electric Motor Version - Maintenance

Ransburg

36

AH-13-01.1

†

DO NOT apply dielectric grease or any

other lubricant to the PTFE seal (Item 8), ce-

ramic seal (Item 5), drive shaft (Item 7), or

collar (Item 1). The application of dielectric

grease or any other lubricant to these com-

ponents can cause premature failure of the

motor.

10. Place the nut (Item 3) onto drive shaft (Item

7) side with threads toward ceramic seal (Item

5). Slide it back on drive shaft as far as it will go.

11. Slip the collar (Item 1) onto the drive shaft

(Item 7), align the two set screws with the two

flats in drive shaft. Secure the collar to the drive

shaft by tightening the two set screws (Item 2).

12. Install the outer O-ring (Item 6) on the drive

shaft.

13. Install the resistor (black ink end first) and

spring into the rear of the drive shaft (Item 7).

Spring must be long enough to contact end of

resistor and motor shaft.

14. Holding the gun assembly with the front of the

barrel angled slightly downward, slide the drive

shaft (Item 7) into the front of the barrel until it

bottoms. Rotate the drive shaft by hand until you

feel the slot engage the motor shaft pin. Tighten

nut (Item 3) to secure the drive shaft to the gun

assembly.

†

If the nut will not thread fully, the shaft is

not engaged. Unscrew and repeat Step 13.

9060 FUSE REPLACEMENT

†

When ever the 9060 power supply is ser-

viced, insure that the power is off to the unit.

1. Insure the power is turned off on the front

panel switch. If possible disconnect the line cord

to the unit.

2. Insert a flat bladed screwdriver into the slot of

the fuse holder. Push the end of the fuse holder

in and turn counter-clock wise to remove the fuse.

3. Inspect the fuse, insure it is the proper fuse

to give the proper protection. If faulty, replace as

required. Extra fuses are supplied with the 9060

and located inside the lid of the supply.

4. Insert the end of the fuse holder back with the

fuse in the center and push down while turning the

holder 1/4 turn clock-wise to lock back in place.

Figure 25: Fuse Location

C A U T I O N

!

C A U T I O N

!

W A R N I N G

!

Advertising