9060 for No. 2 Process Handgun - Operation

CP-13-03.2

16

OPERATION

Figure 7: Controller Start-Up Display

The controller comes preconfigured for the No.
2 Process Handgun from the factory. The
following table lists the display value and
jumper settings for the unit. This table is a
reference

to verify that the gun configuration

jumpers are in their correct positions if unex-
pected behavior is observed.

USE ONLY the gun type configuration

for the No. 2 Process Handgun (80102-
21X). Using the wrong configuration may
allow for operation outside the recom-
mended parameters and values for the
applicator and can result in damage or un
-safe operation

.

!

W A R N I N G

BASIC OPERATIONS


The basic operations are general operations
that are available.

Triggering High Voltage

High voltage is actuated by the presence of an
active trigger signal. This is accomplished by
turning the on-off switch of the No. 2 Process
Handgun to the “on” position. The kV is dis-
played on the kV display, the actual current
draw on the µA display, and the high voltage
light illuminates. Under the µA display is a bar
graph meter that illuminates according to the
actual current draw shown in Figure 8.The
green and yellow regions of the bar graphs
meter indicate output current is in the optimum
range for maximum transfer efficiency. The red
region of the bar graph indicates high output
current causing decreased transfer efficiency.
If high output, check maintenance of applicator
and external equipment of the power supply.

START-UP


After all installation procedures are completed,
operation of the applicator may begin. When
the ON-OFF switch is turned on, the kV display
will show the applicator type the 9060 Controller
is configured for and the µA (microamp) display
will show the current software revision level as
shown in Figure 7. These items are displayed
for approximately 10 seconds.

Type

Description

Jumpers

99

No. 2 Process Handgun

(Electric Motor)

13

START-UP DISPLAY

After the initial start-up delay, the unit will be
configured for the applicator based on the gun
type jumper settings and is ready for standard
operation.

During start-up, the gun on-off switch

should NOT be in the on position. If this
switch is ON it will cause a non-resettable
boot fault (bF) and prevent the unit from
being operated. This is designed to pre-
vent unintended firing of the high-voltage
immediately after start-up. Please refer to
the “Fault Section” of this manual for more
information.

N O T E