9060 for No. 2 Process Handgun - Installation

17

CP-13-03.2

Figure 8: µA Bar Graph Meter Display

Figure 9: Display “High Voltage On” Time

Measuring “High Voltage On”
Time

The 9060 High Voltage Controller records the
amount of time the high voltage is triggered on
up to 99,999 hours. This value is display on the
kV and µA displays of the unit. There are two
registers that retain this information, one that
may be reset, the other that is permanently
retained in memory. The number of hours the
unit’s high voltage has been on may be dis-
played by depressing at the same time the
preset 1 and reset buttons (See Figure 9). The
display will show hours of use for 3 seconds.
This is the resettable register.

To reset this register, press the reset button
while the hours are displayed.

To view the non-resettable register, press the
preset 2 and reset buttons at the same time.
This display will show the hours for 3 seconds.

KV TEST JUMPER


To assist in testing and troubleshooting, a
jumper (J8) has been added to the main PC

If jumper J8 is left covering (shorting)

both terminals, high voltage will be on
whenever the AC power is turned on.

!

W A R N I N G

Use Ransburg Calibrated Equipment

ONLY

for testing and troubleshooting. Re-

fer to the “Parts” section of this manual for
part numbers for testing equipment.

N O T E

SETPOINT OPERATIONS

Voltage Setpoint

The voltage on the 9060 High Voltage Control-
ler, when configured for use with the No. 2
Process Handgun (80102-21X), is NOT adjust-
able. The Electric Motor No. 2 Handgun is
designed to operate at only a set point of
100kV. The display will always show 99kV.

board. By covering (shorting) both terminals of
this jumper, the high voltage of the spray
applicator can be activated. Thus, for testing
and troubleshooting, high voltage output can be
obtained without the need to trigger air through
the spray applicator. After testing, the jumper
must be repositioned so that it covers only
one terminal (open) or the high voltage will
stay on all the time.

See Figure 10 for the

location of KV test jumper J8.

Figure 10: KV Test Jumper Location