Relay board, Power supply 1ps, Power supply 2ps – Ransburg 9060 HV P.S. Electric Motor 80102-21X User Manual

Page 34

Advertising
background image

9060 for No. 2 Process Handgun - Maintenance

29

CP-13-03.2

6. Secure the cabinet lid and plug the

power supply back in.

Relay Board


1. Ensure power supply is unplugged from

AC outlet and open cabinet lid.

2. Unscrew and Remove all wires from the

currently installed relay board.

3. Remove the screws that mount the relay

board to the top of the cascade.

4. Install relay board, tighten retaining screws

(4) to mount relay board on top of the
cascade.

5. Connect the ground lead from ground screw

shown in Figure 7 to the relay board termi-
nal block position 4PL-7.

6. Connect the trigger lead wire from the PC

Mainboard J3-5 connector to relay board
terminal block position 4PL-6.

7. Connect the +V (blue lead) from plug 5PL

on the power supply 2PS to the relay board
terminal block position 4PL-5.

8. Connect the orange lead from the high

voltage connector (1CON) to the relay
board terminal block position 4PL-2.

9. Connect the blue lead from the high voltage

connector (1CON) to the relay board
terminal block position 4PL-3.

10. Secure the cabinet door, replace the fuses,

and reconnect the AC source.

Power Supply 1PS

1. Ensure power supply is unplugged from

AC outlet and open cabinet lid.

2. Remove the (4) screw from the 1PS

cover plate and remove the plate.

3. Remove connectors 1PL and 2PL from

power supply 1PS.

4. Remove the (4) cover plate standoffs

from power supply 1PS and remove the
power supply from the unit.

5. Install new 1SUP power supply (See

“Parts Identification” section of this
manual for part numbers) using the (4)
cover plate standoffs. Ensure larger
terminal strip (2PL) of power supply 1PS
faces the front of unit as shown in Figure
9.

6. Connect connectors 1PL and 2PL to new

power supply and reinstall cover plate.

7. Secure cabinet door and plug power

supply back in.

Power Supply 2PS

1. Remove HV cable from power supply.

2. Ensure power supply is unplugged from

AC outlet and open cabinet lid

3. Remove the (4) screw from the 2PS

cover plate and remove the plate.

4. Remove connectors 5PL and 6PL from

power supply 2PS.

5. Remove the (4) cover plate standoffs

that mount power supply 2PS to the high
voltage multipliers’ aluminum housing.

6. Remove power supply 2PS from the unit.

7. Install the new 24 VDC supply 2PS (See

“Parts Identification” section of this
manual for part numbers). Ensure the

ALWAYS double check that the power

supply is unplugged from its AC outlet be-
fore removing the cover plate from power
supply 1SUP.

!

W A R N I N G