Installation (continued) – Ransburg Evolver SE Robotic Atomizer A12455-XXXXXXXX User Manual

Page 14

Advertising
background image

AA-09-01.1 : Evolver SE

High Voltage Cable and Tubing (removal)

**Ensure high voltage is turned OFF and pressure in ALL air and
fluid lines are at ZERO.

1. High voltage cable: Remove red retaining clip. Push down

on the collet and then pull cable straight out.

2. Air tubing (all): Push down on collet and pull straight out.

3. Fluid tubing (all): Use two wrenches to prevent the fitting

from turning. Loosen nut and ferrule and remove by hand.

INSTALLATION (continued)

Changing Gun Head Angle

1. To change the angle of the gun head, the shoulder screws

need to be removed.

2. Align the threaded holes to the gun head angle position

desired.

3. Install shoulder screws at tighten to a final torque of 15 lbs/

in (1.69 Nm).

Paint Mate Robot

1. Typical tubing bundle management consists of wrapping entire bundle with spiral wrap.

2. Start at approximately 18 inches behind the applicator.

3. Wrap every 2-3 ft.

4. Route tubing through the center arm open area.

5. Secure a strain relief (surgical tubing) from the main support arm and attach to the tubing.

6. Allow at least 2-3 ft. of slack in tubing at the applicator.

7. Tubing on wrist rotation should be held to a maximum rotation of 430°.

8. Cycle program slowly to check for any pinch or catch points.

Advertising