AA-09-01.1 : Evolver SE

SERVICE

Unexpected robot movement can be hazardous. Do not adjust or repair the spray applicator when the
robot is operating or waiting to start. The robot must be locked out and tagged out per OSHA prior to re-
moving the applicator from the robot manifold assembly.

WARNING

Before performing any work on the spray applicator, always flush the fluid passages and blow dry with push-out air, and
wipe the spray applicator clean. Refer to "Gun Cleaning / Service" in the "Maintenance" section, for instructions on how
to properly clean the spray applicator. Depressurize all fluid and air pressures before removing the applicator from its
manifold. Always work in a clear, clean space to minimize part loss and damage.

Eye protection should be worn while servicing gun.

WARNING

As the spray head is removed from the valve manifold assembly, a certain amount of residual fluid may
be present. Care must be taken not to allow the fluid to drain into the high voltage terminal rings or air
passages.

CAUTION

NOTE - Disassemble spray head only enough to remove and replace defective parts. For instance, if only replacing the
front electrode it is not necessary to remove the fluid nozzle.

NOTE - To prevent damage, always lubricate the o-rings located on the underside of the spray head.