APPLICATOR CLEANING (continued)

5. Remove the air cap retainer and air cap. Soak in a solvent if necessary. If paint remains in the air cap holes, clean with a toothpick
or similar soft wood object. Air caps are best cleaned in an ultrasonic cleaner.

6. Remove the air cap locator and fluid tip. Clean using a solvent.

1

2

4

5

3

Never attempt to clean the air cap holes with a wire or other metal object. Doing so may damage the air
cap, resulting in distortion of the spray pattern.

CAUTION

7. Tightly grip the needle and unscrew counter-clockwise to remove the electrode. A short piece of H-2339 tubing (1/4" OD x 0.175"
ID) pressed over the electrode will assist in unscrewing the assembly. If required, use needle nose pliers with masking or duct tape.
Carefully clean with a solvent. Replace any parts that show signs of wear or damage.

1

2

If using needle nose pliers to unscrew the electrode, be very careful. Do not grip on the tapered sealing
surface. If the pliers slip, they could damage the tapered sealing surface of the electrode.

CAUTION

8. Remove fluid nozzle by unscrewing counter-clockwise. Inspect o-ring and all passages for build-up or damage. Clean or replace as
necessary. Lubricate and reinsert o-ring into applicator barrel and reinstall fluid nozzle. Torque fluid nozzle to 25 lbs-in (2.82 Nm).

NOTE - There should be a small gap between the fluid nozzle and the applicator barrel after tightening.