ROUTINE MAINTENANCE SCHEDULE (continued)

Shut Down (or at Shift End)

1. Flush the lines and allow the solvent to remain in the lines. (See "Procedures" in the "Maintenance" section.)

2. Wipe the applicator and robot wrist with a cloth and a suitable, clean non-polar solvent.

Weekly

1. Check the entire system for damage, leaks and paint accumulation.

2. Clean the atomizer assembly.

APPLICATOR CLEANING

Cleaning

1. Flush the paint supply line and the applicator paint passages using a solvent which is compatible with the material being sprayed.
Continue to flush until all traces of paint are gone.

2. Turn off the solvent supply, actuate paint push out air at the color changer and trigger the applicator. Allow all of the fluid to drain
from the spray applicator fluid passages.

3. Clean the exterior surfaces of the spray applicator with a solvent soaked rag.

4. Remove end cap. Removing the end cap releases tension on all internal spray head components. Remove needle spring and valve
spring, which are loose after removing the piston cap.