AquaBlock 2 - Introduction

8

†

If the high voltage power supply does

not have a pneumatic pressure switch,

contact your local Ransburg representative

about adding it to your power supply.

NOTE

System Electrical Current Monitor

The electrical circuit that monitors the electro-

static current that bleeds through the AquaBlock

2 is composed primarily of a microampere meter

located on the face of the cabinet. The electrical

circuit is completed by one wire connected from

the paint supply fitting to the meter and another

wire from the meter to earth ground. The meter

provides an indication of the level of current that

is passing through the AquaBlock 2 from the

electrostatic applicator. This current measure-

ment provides useful information as to the level of

contamination inside the quick disconnect shields,

contamination inside the cabinet, and abnormal

system operation such as quick disconnect (or

fluid seal) leakage, etc.

The scale on the microampere meter is divided

into three zones (refer to "Current Meter" chart).

Each time the 4-way shuttle assembly switches

there is a possibility that the current meter will

show a current reading momentarily. If the needle

on the meter returns slowly to the steady state

current or stays high, this could be an indication

of a problem situation that requires immediate

attention and potential system damage.

Current Meter

0-20

20-50

50+

Current Range

(Microamperes)

Normal Operation Range

Clean Quick-Disconnect Shields

Shut System Down *

Activity

* Possible Damage

LN-9902-00.3