AquaBlock 2 - Maintenance

26

TOOLS REQUIRED TO REBUILD DISCONNECTS

30mm Socket (1 3/16"), 7mm Socket (9/32"), Awl or Rod (1.5mm Diameter (1/16"), Snap

Ring Pliers (Internal Type)

Female Disconnect

After removal of the disconnect from the Aqua-

block assembly, carefully remove the coiled

spring around the body. Inspect the spring for any

damage. If there are any flat spots or kinks to it,

replace the part. Hold the small end of disconnect

in a vise with non-marking jaws. Using a 30mm

(1 3/16) wrench or socket, unscrew the packing

retainer from the main body. Using your finger or

a non-metallic device, push the assembled stem

parts out of the main body from the large end.

Remove the o-ring from the groove near the large

end of the body.

Disassemble the seal carrier assembly as follows:

Using an awl or other similar devise, insert it into

the hole located in the stem through the spring as

a holding devise. Use a 7mm (9/32") nut driver

or socket to unscrew the hex nut. Remove stem

through the front. Remove the piston packing

(black rubber piece) from the seal carrier and re-

place with a new part. Remove the white spring

energized u-cup seal on the exterior of the seal

carrier body. Do not damage the sealing surface

that it is located on. Replace the seal with a new

part.

PROCEDURE FOR

REBUILDING MALE &

FEMALE AQUABLOCK 2

DISCONNECTS

LN-9902-00.3

Ransburg

Advertising