AquaBlock 2 - Maintenance

35

TROUBLESHOOTING GUIDE

General Problem

Possible Causes

Corrective Action

No Paint Flow

1. Quick-disconnect not

engaging fully

2. Low or no paint pressure

3. Contamination in cylinder

4. Low air pressure

1. Low pressure in the paint

supply system.

2. Contamination in cylinder

1. Over-pressure

2. Worn or damaged seal(s)

3. Quick-disconnect misaligned

4. Dry material between seal and

seat

1. Worn or damaged piston

seal(s)

1. High voltage shields missing

2. Contaminated component

surfaces inside AquaBlock

2 cabinet

3. Cylinder leakage

4. Pin hole in tubing and/or

fitting

5. Fluid leaking from tubing

and/or fittings

6. Polyurethane tube shields

missing from tubing

7. Contaminated quick-

disconnect shields

1. Determine why the quick-disconnect is not

engaging and remove obstruction. Ensure

quick-disconnect shields are fully installed.

Replace quick-discount(s).

2. Ensure that paint supply pressure is above 20 psi.

3. Replace or repair cylinder

4. Ensure that air pressure is set to 90 psi

+/-5 psi.

1. Increase paint supply pressure above 20 psi.

2. Replace quick-disconnect(s).

1. Decrease paint supply pressure below 120 psi.

2. Replace quick-disconnect(s).

3. Align quick-disconnect(s).

4. Repair or replace disconnect(s).

1. Replace or repair cylinder.

1. Install high voltage shields ensuring that they

are fully installed.

2. Clean all surfaces with a strong solvent and

rewipe surface with a non-polar solvent.

3. Replace or repair cylinder.

4. Replace pin holed tube and/or fitting and

clean all contaminated surface.

5. Tighten or replace fitting and clean all

contaminated surface.

6. Install polyurethane tube shields.

7. Clean shields or replace.