AquaBlock 2 - Maintenance

21

MAINTENANCE

PERIODIC MAINTENANCE

Shift/Daily

1. Without high voltage applied to the applica-

tor(s) check outside and inside of the AquaBlock

cabinet for any fluid leaks and correct as needed.

2. Flush the AquaBlock 2 fluid lines, cylinder,

etc. with appropriate flushing solvents using

normal color change procedures.

†

The steady state current of the

Aqua-Block 2 refers to the current read-

ing when the 4-way shuttle is in one of

the two end positions.

†

The switching current refers to the

AquaBlock 2 current when the 4-way

shuttle is switching.

NOTE

3. Open the AquaBlock 2 cabinet door and en-

sure free movement of 4-way Shuttle by pushing

back and forth by hand.

4. Remove the eight (8) Quick-Disconnect

Shields by turning counter-clockwise.

5. Clean Quick-Disconnect Shields using appro-

priate solvent and a soft rag or soft bristle brush.

6. Clean the eight (8) Quick-Disconnects using

an appropriate solvent and a soft rag or soft bristle

brush.

7. Install the eight (8) Quick-Disconnect Shields

by turning clockwise and hand tighten.

8. Close the AquaBlock 2 cabinet door.

9. With paint loaded into the AquaBlock 2 and

high voltage applied to the applicator(s) check the

steady state current of the AquaBlock 2 system on

the current meter on the door of the cabinet(refer

to "Current Meter" chart in the "Introduction" sec-

tion).

†

The system may be flushed out with a

blend of water and solvent. A water/solvent

mixture (Butyl Cellosolve or Butyl Carbitol)

should be left in the system when not in

use. Check with your coating supplier for

recommended cleaning mixtures. DO NOT

USE TAP WATER. DEIONIZED WATER IS

ACCEPTABLE.

†

Purging the system with compressed

air only or a combination of compressed air

and flushing fluid may leave deposits of dry

coating material in the system which may

cause damage to the seals and internal

surfaces of the components.

C A U T I O N

!

C A U T I O N

!

†

Prior to performing any maintenance

on the AquaBlock 2, shut off, relieve, and

lock out all pressure and power sources,

including com-pressed air, flush material and

coating supply systems, and high voltage

power supplies.

W A R N I N G

!