AquaBlock 2 - Installation
17
AquaBlock 2 Installation Checklist
o
All users must carefully read and understand the Safety Precautions and all instructions before
using the AquaBlock 2 system.
o
Installation must comply with appropriate local, state, and national codes governing ventilation,
fire protection, operation, maintenance, and housekeeping. Refer to OSHA, NFPA-30, NFPA-33,
and the customer's insurance requirements.
o
All coating materials, solvents, etc. used in the AquaBlock 2 system must have a flash point of
equal to or above 100°F.
o
Filtration is required for the paint supply as well as any water or solvent supply connected to the
system.
o
All electrically conductive objects, with the exception of those required by the process, must be
grounded. This includes all metallic fluid lines, fittings, etc.
o
All connections to ground must be made individually from each component.
o
The ground lug on the AquaBlock 2 cabinet must be connected to ground.
o
The coating material supply to the AquaBlock 2 must be grounded.
o
An 18–24-inch length of electrically non-conductive fluid line must be used between the grounded
fluid supply and the AquaBlock 2 fluid inlet fitting.
o
The high voltage interlock from the AquaBlock 2 assembly must be installed and functional.
o
Main air supply to the AquaBlock 2 cabinet must be 90 psi +/- 5 psi.
o
The fluid inlet pressure at the AquaBlock 2 enclosure must never exceed 100 psi or be less than
20 psi.
o
The electrostatic voltage must never exceed 90kV.
o
Material to be sprayed in not of an emulsion typed.
LN-9902-00.3