Overview – Robinair 16900 Refrigerant Identifier User Manual

Page 7

Advertising
background image

16900 Refrigerant Identifier

5

Overview

Sample gas is admitted into the instrument through the supplied sample

hose and presented to the sensing devices. The instrument provides a

digital readout of refrigerant purity, a pass or fail condition, and the

amount of contamination.

A sample is considered to be pure, or passed, if the concentration has

been determined to be 98% or greater by weight of a single refrigerant

(R-134a or R-12). The instrument also provides an indication of

unknown compounds that may be R-22, hydrocarbons, or other

refrigerants commonly used in blended refrigerant types.

Operating instructions are provided to the user through display prompts

to avoid mistakes and erroneous readings.

The Identifier provides the refrigerant technician with knowledge

of refrigerant purity and protection against equipment and air

conditioning system damage resulting from contamination.