7) Remove the motor.
䈄 Remove the affixing bolts (M4 × 15, 4 pcs.) using an Allen wrench of 3 mm across flats.
'HFRXSOHGPRWRU
3XOORXWWKHPRWRUE\KDQG
8) Install a new motor.
$IWHUFRQILUPLQJWKDWWKHDQJOHVRISURMHFWLRQVDQGGHSUHVVLRQVRQWKHFRXSOLQJVDUHDOLJQHGWLJKWHQWKH
affixing bolts (M4 × 15, 4 pcs.).
(Use an Allen wrench of 3 mm across flats.)
Tightening torque: 176 N·cm (18 kgf·cm)